Highlights Issues of MRI that are relevant for radiation oncologists are addressed. Radiation oncology requires dedicated scan protocols. Use of diagnostic protocols is not recommended for radiotherapy. MR images must be made in treatment position with the standard positioning devices. Safety screening prior to entering the MRI room is crucial.
Purpose: To analyze the effect of computing radiation dose on automatically generated MR‐based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast‐field dual‐echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out‐of‐phase (echo 1) and in‐phase images (echo 2) allowed for water and fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re‐computed on the simCT in pinnacle3. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.
Until recently Traffic Light Protocols (TLP) have been developed to recognize and react to Anatomical Changes (ACs) seen on Cone Beam Computer Tomography (CBCT) scans for the most common treatment sites. This involves alerting the Radiation Oncologist (RO), handing over findings, and RO providing the final decision, making it quite labour-intensive for the ROs as well as the Radiation Therapists (RTTs). A new approach was developed to act on ACs: the Take Action Protocol (TAP). In this protocol the RTTs do not only have a role in detecting ACs, but also decide on the appropriate action and follow up, resulting in a significant shift in responsibility. In this study we present the TAP and evaluated the benefit and outcomes of the implementation of TAP compared to the TLP. During a pilot period of six months the TAP was applied for 34 bladder and prostate patients. In 2 bladder and 6 prostate patients further decision making by an RO was required (compared to all 34 in the TLP), showing a large reduction in workload. ACs were accurately assessed by RTTs in >99% of the cases. In 5/34 patients RTTs specialized in Image Guided Radiotherapy provided additional instructions to improve accurate use of the TAP. Two surveys conducted by both ROs and RTTs on the TLP and TAP showed that the perceived involvement of the ROs and burden of responsibility for RTTs was comparable between the two protocols. The identification of patients with truly clinical relevant ACs and the adaptation of treatment for the remaining fractions improved according to ROs and RTTs responses. The TAP provides a better balance between workload and efficiency in relation to the clinical relevance of acting on ACs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.