The present work describes a rapid and accurate amperometric technique for the determination of acetaminophen (ACT) in pharmaceutical preparations and human blood serum, based on electrocatalytic oxidation of ACT at a glassy carbon electrode modified by cadmium pentacyanonitrosylferrate (CdPCNF) film. The electrocatalytic response of the modified GC electrode was linear over the concentration of 1.64-52.90 μM. The limit of detection was found to be 2.04 μM by amperometric technique. The method was successfully utilized for the determination of ACT in various pharmaceutical preparations and the results have been statistically compared with those obtained by the official method. The interference of some pharmaceutical and biological compounds was investigated. The results of interference study showed that the Nafion-coated CdPCNF|GC electrode can be utilized as a selective amperometric sensor for acetaminophen determination in human blood serum. The mean value of rate constant k for catalytic reaction, and the diffusion coefficient of ACT (D) in the phosphate buffer solution of pH 7.2 were found to be 4.27 10 2 M -1 s -1 , and (4.25 ± 0.33) 10 -6 cm 2 s -1 , respectively.
Two new methods based on cloud point extraction (CPE) technique were developed and optimized for the extraction and preconcentration of oxazepam from human urine, as an azo or fluorescent derivative. The first method is a spectrophotometric one, which is based on the acid hydrolysis of the oxazepam to a benzophenone, diazotization of the benzophenone, and then the coupling with oxine to form an azo dye. The second method is a spectrofluorimetric one, which involves reduction of the target compound using Zn°/HCl at room temperature with the formation of a highly fluorescent derivative. The main factors affecting the chemical reactions and CPE were investigated and optimized systematically. Under optimum experimental conditions, the calibration graphs were linear in the range of 0.1 to 1.5 (0.05 to 2.0) µg/ml with correlation coefficients of 0.9989 (0.9985), for the CPE-spectrophotometric (CPE-spectrofluorimetric) method. The limit of detection was found to be 0.034 (0.018) µg/ml and the relative standard deviation was calculated to be 1.35 (2.52)%. Recoveries in the spiked samples ranged from 87 to 94%. Finally, the proposed methods were applied to the determination of oxazepam in human urine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.