In this investigation, the gamma photon shielding properties for the (Al:Si) and (Al+Na):Si dopped ISG glasses were investigated by using Photon Shielding and Dosimetry (Phy-X / PSD) software for the selected energy range. The obtained results showed that the highest MAC value belong to ISG-A00N glass. It was seen that the MAC values which were examined at all energies changed in harmony with WinXCom. Substituting an atomic fraction of (Al:Si) with (Al+Na):Si resulted in a reduction of the total atomic cross-section of the glass, which lowered the mass attenuation coefficient (MAC). In this study, computations were made for glasses with SiO 2 , Al 2 O 3 , B 2 O 3 , Na 2 O, CaO and ZrO 2 content given with ISG-C, ISG-A00, ISG-A12, ISG-A22, ISG-A00N, ISG-A11N, ISG-A18N and ISG-A23N codes. MAC, LAC, HVL, TVL, Z eff , N eff , C eff Z eq , EBF, EABF and FNRCS calculations were applied to assess the radiation protection parameters by using Phy-X/PSD software. In addition, MSP and PR values were calculated by using the SRIM code. In fact, each obtained parameter provides us very important information on radiation protection, and these methods are frequently used in the literature. ISG-A00N glasses were observed to have the highest attenuation coefficient. Thus, the MAC value gradually decreased as the Al, Na and Si contents increased. Likewise, the HVL, TVL and MFP values changed coherent with this. Moreover, Z eff and N eff values were seen in the ISG-A00N sample to take the maximum values to each other inversely. The most effective glass sample was seen as ISG-A00N glass at the mean free path penetration power of MSP and PR values. When all the results were evaluated, ISG-A00N glass which has the highest Si and Ca contents and density was found to be the glass with the best radiation shielding feature. It is also noteworthy that this glass does not contain any Al component. As the results of the investigation, it was found out that a very small doped of the Si increases the radiation shielding feature on the glass. It was seen that the ISG-A23N had the lowest ∑R value. The obtained results revealed that the ISG-A00N>ISG-A00>ISG-C>ISG-A12>ISG-A11N>ISG-A22>ISG-A18N>ISG-A23N samples, in ascending order that attenuators for low energy radiations.