Delamination of flakes in glass containers used for primary drug packaging has become a serious quality concern in recent years. Because glass delamination typically occurs weeks/months after filling and there are a variety of container, processing and drug formulation factors that contribute to glass delamination, it is recommended according to USP <1660> (1) to conduct suitable container/drug product compatibility tests. Such predictive studies should give results that allow a graduated assessment for increasing risk of delamination that can be used to detect early stages of this phenomenon and to help to select appropriate container/formulation systems to proactively prevent delamination instead of just monitoring for the presence/absence of flakes. This work demonstrates the capability of a container compatibility testing approach by determining the impact of three different model buffer/solution systems (citrate, phosphate and sodium bicarbonate) with the delamination behavior of two different types of 2 mL glass vials, standard quality and delamination controlled quality. Vials of each type were filled and stored up to 48 weeks at 40 °C. Using a USP <1660>-compatible package of different analytical methods clearly demonstrates the significant influence of both vial quality and chemistry of the content on glass delamination propensity.LAY ABSTRACT The detachment of flakes from the inner surface of a glass container-also referred to as delamination-has become a serious quality concern over the last years for the pharmaceutical industry. Chapter <1660> of the United Stated Pharmacopeia therefore recommends performing predictive screening studies with the drug formulation and the glass container to evaluate the risk of delamination in an early stage of the drug development. Predictive screening studies have been performed with three different representative buffer/solution and glass vials of two different quality steps (standard and delamination controlled). The results demonstrate the capability of container compatibility testing and the influence of vial quality and chemistry of the content on glass delamination propensity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.