In some experimental conditions the electron saturation current of a cylindrical probe placed in a magnetized plasma and oriented along the magnetic field lines shows a large increase when the probe is positively biased with respect to plasma potential. The increase might double the electron saturation current which is followed by a negative slope of the current-voltage characteristic when the positive bias of the probe is further increased. This particular behavior was investigated versus probe length (0 − 5 mm) and radius, probe orientation with respect to the magnetic field lines, magnetic field strength (up to 0.42 T), gas nature and pressure, respectively. The increase of both electron current intensity and negative slope are well pronounced starting with a certain length of the probe and strongly dependent on probe orientation along the magnetic field lines. These particularities are also more pronounced with increasing of both magnetic field strength and mass of the gas atoms. Strong oscillations of the probe current are present in the negative slope region of the probe characteristic.Moreover, the light intensity emitted by plasma volume, where the probe is located, is also dependent on the probe bias. It shows a clear sharp maximum around plasma potential. A qualitative explanation of the probe characteristics with a negative slope obtained with the cylindrical probe is proposed.
Pilot-PSI is a linear plasma device designed for investigations of plasma-surface interaction. A cascaded-arc plasma source operated in argon or/and hydrogen generates a high-density plasma that is magnetically confined on the vessel's axis, resulting a plasma column of about 1-2 cm in diameter which interacts with a solid target. A multi-channel analyzer was constructed to study the radial distribution of the ion flux at the target surface. The analyzer was placed in the centre of Pilot-PSI target and current-voltage characteristics were drawn for five collectors disposed at different radial positions. The ion flux was estimated from the ion part of the current-voltage characteristic for each collector. For densities lower than 10 19 m −3 (significantly below the maximum performance of Pilot-PSI), fluxes of up to 10 23 ions/m 2 s were measured. A difference of a factor four was measured between the maximum ion flux in the centre of the target and the flux at the edge, at a radial position of 1 cm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.