The novel urinary biomarker-based SelectMDx score is a promising tool in PCa detection. This study showed promising results regarding the correlation between the SelectMDx score and mpMRI outcomes, outperforming PCA3. Our results suggest that this risk score could guide clinicians in identifying patients at risk for significant PCa and selecting patients for further radiological diagnostics to reduce unnecessary procedures.
Background
Risk stratification in men with suspicion of prostate cancer (PCa) requires reliable diagnostic tests, not only to identify high-grade PCa, also to minimize the overdetection of low-grade PCa, and reduction of “unnecessary” prostate MRIs and biopsies. This study aimed to evaluate the SelectMDx test to detect high-grade PCa in biopsy-naïve men. Subsequently, to assess combinations of SelectMDx test and multi-parametric (mp) MRI and its potential impact on patient selection for prostate biopsy.
Methods
This prospective multicenter diagnostic study included 599 biopsy-naïve patients with prostate-specific antigen level ≥3 ng/ml. All patients underwent a SelectMDx test and mpMRI before systematic transrectal ultrasound-guided biopsy (TRUSGB). Patients with a suspicious mpMRI also had an in-bore MR-guided biopsy (MRGB). Histopathologic outcome of TRUSGB and MRGB was used as reference standard. High-grade PCa was defined as ISUP Grade Group (GG) ≥ 2. The primary outcome was the detection rates of low- and high-grade PCa and number of biopsies avoided in four strategies, i.e., (1) SelectMDx test-only, (2) mpMRI-only, (3) SelectMDx test followed by mpMRI when SelectMDx test was positive (conditional strategy), and (4) SelectMDx test and mpMRI in all (joint strategy). A positive SelectMDx test outcome was a risk score of ≥−2.8. Decision curve analysis (DCA) was performed to assess clinical utility.
Results
Prevalence of high-grade PCa was 31% (183/599). Thirty-eight percent (227/599) of patients had negative SelectMDx test in whom biopsy could be avoided. Low-grade PCa was not detected in 35% (48/138) with missing 10% (18/183) high-grade PCa. Yet, mpMRI-only could avoid 49% of biopsies, not detecting 4.9% (9/183) of high-grade PCa. The conditional strategy reduces the number of mpMRIs by 38% (227/599), avoiding biopsy in 60% (357/599) and missing 13% (24/183) high-grade PCa. Low-grade PCa was not detected in 58% (80/138). DCA showed the highest net benefit for the mpMRI-only strategy, followed by the conditional strategy at-risk thresholds >10%.
Conclusions
SelectMDx test as a risk stratification tool for biopsy-naïve men avoids unnecessary biopsies in 38%, minimizes low-grade PCa detection, and misses only 10% high-grade PCa. Yet, using mpMRI in all patients had the highest net benefit, avoiding biopsy in 49% and missing 4.9% of high-risk PCa. However, if mpMRI availability is limited or expensive, using mpMRI-only in SelectMDx test positive patients is a good alternative strategy.
The definition of an in vivo nodal anatomical baseline is crucial for validation of representative lymph node dissections and accompanying pathology reports of pelvic cancers, as well as for assessing a potential therapeutic effect of extended lymph node dissections. Therefore the number, size and distribution of lymph nodes in the pelvis were assessed with highresolution, large field-of-view, 7 Tesla (T) magnetic resonance imaging (MRI) with frequency-selective excitation. Materials and methods We used 7 T MRI for homogeneous pelvic imaging in 11 young healthy volunteers. Frequency-selective imaging of water and lipids was performed to detect nodal structures in the pelvis. Number and size of detected nodes was measured and size distribution per region was assessed. An average volunteer-normalized nodal size distribution was determined. Results In total, 564 lymph nodes were detected in six pelvic regions. Mean number was 51.3 with a wide range of 19-91 lymph nodes per volunteer. Mean diameter was 2.3 mm with a range of 1 to 7 mm. 69% Was 2 mm or smaller. The overall size distribution was very similar to the average volunteer-normalized nodal size distribution. Conclusions The amount of in vivo visible lymph nodes varies largely between subjects, whereas the normalized size distribution of nodes does not. The presence of many small lymph nodes
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.