This study describes the surface roughness of heat-treated Ti6Al4V ELI samples without surface finishing (as-built condition) depending on the position of the build plate. Surface roughness was studied at the top and side surfaces of horizontal and vertical samples using a profilometer and Scanning Electron Microscopy. Morphology of tested samples is shown. It was shown that the top and side surfaces of vertical and horizontal samples had different morphologies, but they had fairly close roughness values, since the formation of roughness was mainly associated with sticking of the powder material both on the upper surface of the samples and on the side surfaces. It was found that samples that were far away from the argon inlet and recoater start line had higher surface roughness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.