Despite being the most common benign intracardiac tumour with an excellent prognosis after surgical excision the incidence of atrial myxoma (except at autopsy) is unknown. We reviewed all patients admitted to the National Cardiac Surgery Unit (n = 26) with an atrial myxoma over a fifteen year period (1977-1991) to compile national incidence data and assess pre-operative diagnosis, management, surgical technique, and outcome. Preoperative symptoms were: congestive cardiac failure (12 patients), embolism (8 patients), constitutional (3 patients), asymptomatic (2 patients) and tachyarrhythmia (1 patient). The diagnosis was confirmed by 2D echocardiography alone in thirteen patients and by a combination of echocardiography and angiography in thirteen patients. At operation the site of the tumour was left atrial in 24 patients and bi-atrial in two patients. All cases were confirmed by histology. All patients made a good post-operative recovery, although one patient survived a pulmonary embolus and one patient developed a deep venous thrombosis. There has been one late death (five months after surgery) from a cerebrovascular accident. Serial echocardiography has revealed one recurrence to date (8 years after surgery). The surgical incidence of these tumours in the Republic of Ireland over the study period was 0.5 atrial myxomas/million population/year. Although rare atrial myxomas are the most important cardiac tumours to diagnose as the results from surgery are excellent.
ObjectivesThis study explores the opinions of orthopaedic healthcare professionals regarding the opportunities and challenges of using wearable technology in rehabilitation. It continues to assess the perceived impact of an exemplar exercise biofeedback system that incorporates wearable sensing, involving the clinician in the user-centred design process, a valuable step in ensuring ease of implementation, sustained engagement and clinical relevance.DesignThis is a qualitative study consisting of one-to-one semi-structured interviews, including a demonstration of a prototype wearable exercise biofeedback system. Interviews were audio-recorded and transcribed, with thematic analysis conducted of all transcripts.SettingThe study was conducted in the orthopaedic department of an acute private hospital.ParticipantsTen clinicians from a multidisciplinary team of healthcare professionals involved in the orthopaedic rehabilitation pathway participated in the study.ResultsParticipants reported that there is currently a challenge in gathering timely and objective data for the monitoring of patients in orthopaedic rehabilitation. While there are challenges in ensuring reliability and engagement of biofeedback systems, clinicians perceive significant value in the use of wearable biofeedback systems such as the exemplar demonstrated for use following total knee replacement.ConclusionsClinicians see an opportunity for wearable technology to continuously track data in real-time, and feel that feedback provided to users regarding exercise technique and adherence can further support the patient at home, although there are clear design and implementation challenges relating to ensuring technical accuracy and tailoring rehabilitation to the individual. There was perceived value in the prototype system demonstrated to participants which supports the ongoing development of such exercise biofeedback platforms.
The majority of wearable sensor-based biofeedback systems used in exercise rehabilitation lack end-user evaluation as part of the development process. This study sought to evaluate an exemplar sensor-based biofeedback system, investigating the feasibility, usability, perceived impact and user experience of using the platform. Fifteen patients participated in the study having recently undergone knee replacement surgery. Participants were provided with the system for two weeks at home, completing a semi-structured interview alongside the System Usability Scale (SUS) and user version of the Mobile Application Rating Scale (uMARS). The analysis from the SUS (mean = 90.8 [SD = 7.8]) suggests a high degree of usability, supported by qualitative findings. The mean adherence rate was 79% with participants reporting a largely positive user experience, suggesting it offers additional support with the rehabilitation regime. Overall quality from the mean uMARS score was 4.1 out of 5 (SD = 0.39), however a number of bugs and inaccuracies were highlighted along with suggestions for additional features to enhance engagement. This study has shown that patients perceive value in the use of wearable sensor-based biofeedback systems and has highlighted the benefit of user-evaluation during the design process, illustrated the need for real-world accuracy validation, and supports the ongoing development of such systems.
Reparative techniques can be successfully applied to congenital mitral valve disease, especially in children less than 1 year of age, and can be accomplished with a low hospital mortality and acceptable long term survival rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.