We propose a circular scanning system combining a single pair of gamma-ray source and detector to minimize the size of the measurement system. Unlike computerized tomography using an X-ray tube, a low photon-flux occurs in that using gamma rays. To correctly process sparsely sampled and highly noisy data retrieved from the system, we used total-variation minimization for image reconstruction and compared its performance to that of other methods on images in 64 × 64 matrices with 180, 90, and 45 projections. The insufficient projection data retrieve higher quality images for iterative reconstruction, expectation maximization, and projection onto convex sets with total variation than for the conventional filtered back-projection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.