A set of materials—titanium, copper, and germanium—has been experimented with at the OMEGA laser facility [Boehly, Opt. Commun. 133, 495 (1997)] by irradiating thin foils with a prepulse prior to a main pulse with variable delay, in order to design efficient x-ray laser-sources for backlighting, material testing, and code validation. This concept led to increasing factors from 2 to 4 comparing to cases without prepulse, in the experimental conditions. As a result, high multi-keV x-ray conversion rates have been obtained: 9% for titanium around 4keV, 1% for copper around 8keV, and 2.5 to 3% for germanium around 10keV, which places these pre-exploded metallic targets close to the gas with respect to their performance, with wider energy range. A good agreement with hydroradiative code FCI2 [Schurtz, Phys. Plasmas 7, 4238 (2000)] calculations is found for titanium and copper on all diagnostics, with nonlocal-thermal-equilibrium atomic physics and, either nonlocal thermal conduction taking self-generated B-fields into account, or limited thermal conduction with intensity-dependent factor f. The results for germanium indicate that dielectronic processes could play a more significant role when higher irradiation intensity on higher Z material.
The x-ray yields from laser-irradiated germanium-doped ultra-low-density aerogel plasmas have been measured in the energy range from sub-keV to ≈15 keV at the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The targets’ x-ray yields have been studied for variation in target size, aerogel density, laser pulse length, and laser intensity. For targets that result in plasmas with electron densities in the range of ≈10% of the critical density for 3ω light, one can expect 10–11 J/sr of x rays with energies above 9 keV, and 600–800 J/sr for energies below 3.5 keV. In addition to the x-ray spectral yields, the x-ray temporal waveforms have been measured and it is observed that the emitted x rays generally follow the delivered laser power, with late-time enhancements of emitted x-ray power correlated with hydrodynamic compression of the hot plasma. Further, the laser energy reflected from the target by plasma instabilities is found to be 2%–7% of the incident energy for individual beam intensities ≈1014–1015 W/cm2. The propagation of the laser heating in the target volume has been characterized with two-dimensional imaging. Source-region heating is seen to be correlated with the temporal profile of the emitted x-ray power.
Multi-keV x-ray generation from low-density (27±7mg∕cm3) nanofiber-cotton targets composed of titanium dioxide has been investigated. The cotton targets were heated volumetrically and supersonically to a peak electron temperature of 2.3keV, which is optimal to yield Ti K-shell x rays. Considerable enhancement of conversion efficiency [(3.7±0.5)%] from incident laser energy into Ti K-shell x rays (4–6keV band) was attained in comparison with that [(1.4±0.9)%] for a planar Ti-foil target.
In the context of target design for multi-keV x-ray laser-produced experiments, the concept of exploding metallic thin foils by two laser pulses delayed in time has been tested at the OMEGA laser facility [J. M. Soures, R. L. McCrory, C. P. Verdon et al., Phys. Plasma 3, 2108 (1996)]. The first laser pulse creates an underdense plasma (ne∕nc≈0.2), and the second laser pulse heats the plasma plume which produces strong line emission from the titanium K shell (Heα at 4.7 keV and Hα at 4.9 keV). Six OMEGA beams (500-ps duration) for the prepulse and nine beams (1-ns duration) for the heating pulse irradiate one side of the foil. Different experimental conditions have been investigated in order to optimize the conversion efficiency enhancement on titanium foils. The influences of the foil thicknesses (5 and 6 μm), the delays (3, 4, and 5 ns) between the laser pulses, and the laser intensities (1.3 and 2.2×1015Wcm−2) have been tested. The absolute output power was measured by a set of filtered x-ray diodes, giving conversion efficiencies (CEs) up to 3.6% in 2π for energies above 4 keV with a preformed plasma, to be compared to the case without a prepulse where the CE is 1.5%. This double-pulse concept in this case shows an increase of CE by a factor of 2.4 for titanium thin foils. CE up to 4.9% has been reached with a laser intensity of 2.2×1015Wcm−2.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.