This study assesses the influence of atmospheric plasma spraying parameters on splat stacking and porosity formation in bioglass coatings prepared from commercial powders. Coating samples were deposited on stainless steel substrates using spraying parameters established through numerical simulations. Different Ar-H2 mixtures were used as the forming gas, and plasma current and spraying distance were varied. Coating microstructure and phase composition were determined by SEM and XRD analysis. Although numerical simulations for each parameter set predicted a suitable Sommerfeld number for proper splat stacking, Na2O and P2O5 volatilization occurred during spraying, promoting the formation of porosity in the coatings. Denser coatings were obtained, however, by adjusting the gas mixture ratio, plasma current, and spraying distance such that enthalpy of the plasma jet is sufficient to overcome the glass transition temperature of the powder and at the same time avoid the evaporation of volatile oxides.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.