One of the crucial factors for short- and long-term clinical success of total hip arthroplasty cementless implants is primary stability. Indeed, motion at the bone-implant interface above 40 μm leads to partial bone ingrowth, while motion exceeding 150 μm completely inhibits bone ingrowth. The aim of this study was to investigate the effect of two cementless femoral stem designs with different lengths on the primary stability. A finite element model of a composite Sawbones(®) fourth generation, implanted with five lengths of the straight prosthesis design and four lengths of the curved prosthesis design, was loaded with hip joint and abductor forces representing two physiological activities: fast walking and stair climbing. We found that reducing the straight stem length from 146 to 54 mm increased the average micromotion from 17 to 52 μm during fast walking, while the peak value increased from 42 to 104 μm. With the curved stem, reducing length from 105 to 54 mm increased the average micromotion from 10 to 29 μm, while the peak value increased from 37 to 101 μm. Similar findings are obtained for stair climbing for both stems. Although the present study showed that femoral stem length as well as stem design directly influences its primary stability, for the two femoral stems tested, length could be reduced substantially without compromising the primary stability. With the aim of minimising surgical invasiveness, newer femoral stem design and currently well performing stems might be used with a reduced length without compromising primary stability and hence, long-term survivorship.
Three-dimensional (3D) finite element (FE) models are commonly used to analyze the mechanical behavior of the bone under different conditions (i.e., before and after arthroplasty). They can provide detailed information but they are numerically expensive and this limits their use in cases where large or numerous simulations are required. On the other hand, 2D models show less computational cost, but the precision of results depends on the approach used for the simplification. Two main questions arise: Are the 3D results adequately represented by a 2D section of the model? Which approach should be used to build a 2D model that provides reliable results compared to the 3D model? In this paper, we first evaluate if the stem symmetry plane used for generating the 2D models of bone-implant systems adequately represents the results of the full 3D model for stair climbing activity. Then, we explore three different approaches that have been used in the past for creating 2D models: (1) without side-plate (WOSP), (2) with variable thickness side-plate and constant cortical thickness (SPCT), and (3) with variable thickness side-plate and variable cortical thickness (SPVT). From the different approaches investigated, a 2D model including a side-plate best represents the results obtained with the full 3D model with much less computational cost. The side-plate needs to have variable thickness, while the cortical bone thickness can be kept constant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.