Abstract-Experimental studies have shown that in hypertrophy and heart failure, accumulation of microtubules occurs that impedes sarcomere motion and contributes to decreased ventricular compliance. We tested the hypothesis that these changes are present in the failing human heart and that an entire complex of structural components, including cytoskeletal, linkage, and extracellular proteins, are involved in causing functional deterioration. In explanted human hearts failing because of dilated cardiomyopathy (ejection fraction Յ20%), expression of ␣-and -tubulin, desmin, vinculin, fibronectin, and vimentin was determined by Northern and Western blot analysis and compared with normal myocardium from explants not used for transplantation. The mRNA for ␣-and -tubulin was increased to 2.
Cellular degeneration rather than adaptation is present in hibernating myocardium. The consequence is progressive diminution of the chance for complete structural and functional recovery after restoration of blood flow. The practical consequence from this study should be early revascularization in patients showing areas of hibernating myocardium.
The hemodynamic and neurohumoral effects of a single oral dose (0.4 mg) of the novel centrally acting antihypertensive agent moxonidine were investigated over 4 hours in ten patients with essential hypertension (WHO I-II). Pulmonary pressure indices and cardiac output were determined both at rest and during ergometric exercise by means of Swan-Ganz catheterization. Blood pressure was measured by sphygmomanometry and in the brachial artery. Moxonidine induced a significant fall in blood pressure over the 4-hour observation period from 176/105 mmHg to 158/95 mmHg (p less than 0.01), accompanied by a decrease in systemic vascular resistance from 1695 to 1427 dyn.sec/cm5 (p less than 0.01). Cardiac output remained unchanged, while heart rate increased slightly from 69 to 75 beats/min (p less than 0.01). No significant changes were recorded for either pulmonary artery pressure or pulmonary vascular resistance. Plasma levels of noradrenaline (337 vs. 224 pg/ml) and renin (2.6 vs 2.0 ng/ml/hr) activity fell significantly after moxonidine (p less than 0.05), both at rest and during exercise. Although aldosterone plasma levels fell slightly, level of angiotensin II and ANF remained unchanged. Moxonidine has favorable effects on hemodynamics and the neurohumoral system in patients with essential hypertension and is well tolerated at the dose administered.
This report describes the distribution of automatically measured values of enhanced arrhythmia detection parameters such as "rate stability" and "rate onset" in various forms of spontaneous arrhythmia episodes in patients treated with a new, third-generation, tiered therapy implantable cardioverter defibrillator (ICD). The study population consisted of 27 patients who received the Ventak PRxII cardioverter defibrillator, which provides extensive diagnostic options such as electrogram storage capabilities, and the ability to store measured values of additional arrhythmia detection parameters such as rate stability and rate onset during spontaneous arrhythmia episodes. During a follow-up period of 11.1 +/- 5.2 months, this device detected 264 arrhythmia episodes. The analysis of stored electrograms revealed 13 episodes of sinus tachycardia, 52 episodes of atrial tachyarrhythmias, and 201 episodes of monomorphic ventricular tachycardias (VTs). The mean measured values of rate stability and rate onset were: 2.2 +/- 0.9 msec, 0% in sinus tachycardias; 41.0 +/- 24.1 msec, 8.5% +/- 9.5% in atrial tachyarrhythmias; and 7.8 +/- 6.0 msec, 30.6% +/- 12.1% in monomorphic VTs. There was a wide zone of overlapping measured values for rate stability and rate onset in ventricular and nonventricular rhythms. No episode of VT showed a measured rate stability criterion > 35 msec. The subanalysis of arrhythmia episodes presenting with a heart rate < 160 beats/min revealed no episode of VT with a rate stability value > 24 msec. The calculated, rate dependent specificities for these programmed rate stability parameters in detecting VTs were 46.2% and 81.8%, respectively. The analysis of the rate onset algorithm revealed no comparable relationship between sensitivity and specificity in the detection of VTs.(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.