The general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C) was used for the simulation of x-ray spectra in diagnostic radiology and mammography. The electrons were transported until they slow down and stop in the target. Both bremsstrahlung and characteristic x-ray production were considered in this work. We focus on the simulation of various target/filter combinations to investigate the effect of tube voltage, target material and filter thickness on x-ray spectra in the diagnostic radiology and mammography energy ranges. The simulated x-ray spectra were compared with experimental measurements and spectra calculated by IPEM report number 78. In addition, the anode heel effect and off-axis x-ray spectra were assessed for different anode angles and target materials and the results were compared with EGS4-based Monte Carlo simulations and measured data. Quantitative evaluation of the differences between our Monte Carlo simulated and comparison spectra was performed using student's t-test statistical analysis. Generally, there is a good agreement between the simulated x-ray and comparison spectra, although there are systematic differences between the simulated and reference spectra especially in the K-characteristic x-rays intensity. Nevertheless, no statistically significant differences have been observed between IPEM spectra and the simulated spectra. It has been shown that the difference between MCNP simulated spectra and IPEM spectra in the low energy range is the result of the overestimation of characteristic photons following the normalization procedure. The transmission curves produced by MCNP4C have good agreement with the IPEM report especially for tube voltages of 50 kV and 80 kV. The systematic discrepancy for higher tube voltages is the result of systematic differences between the corresponding spectra.
Different computational methods based on empirical or semi-empirical models and sophisticated Monte Carlo calculations have been proposed for prediction of x-ray spectra both in diagnostic radiology and mammography. In this work, the x-ray spectra predicted by various computational models used in the diagnostic radiology and mammography energy range have been assessed by comparison with measured spectra and their effect on the calculation of absorbed dose and effective dose (ED) imparted to the adult ORNL hermaphroditic phantom quantified. This includes empirical models (TASMIP and MASMIP), semi-empirical models (X-rayb&m, X-raytbc, XCOMP, IPEM, Tucker et al., and Blough et al.), and Monte Carlo modeling (EGS4, ITS3.0, and MCNP4C). As part of the comparative assessment, the K x-ray yield, transmission curves, and half value layers (HVLs) have been calculated for the spectra generated with all computational models at different tube voltages. The measured x-ray spectra agreed well with the generated spectra when using X-raytbc and IPEM in diagnostic radiology and mammography energy ranges, respectively. Despite the systematic differences between the simulated and reference spectra for some models, the student's t-test statistical analysis showed there is no statistically significant difference between measured and generated spectra for all computational models investigated in this study. The MCNP4C-based Monte Carlo calculations showed there is no discernable discrepancy in the calculation of absorbed dose and ED in the adult ORNL hermaphroditic phantom when using different computational models for generating the x-ray spectra. Nevertheless, given the limited flexibility of the empirical and semi-empirical models, the spectra obtained through Monte Carlo modeling offer several advantages by providing detailed information about the interactions in the target and filters, which is relevant for the design of new target and filter combinations and optimization of radiological imaging protocols.
Despite all advantages associated with high-energy radiotherapy to improve therapeutic gain, the production of photoneutron via interaction of high-energy photons with high atomic number (Z) materials increases undesired dose to the patient and staff. Owing to the limitation and complication of experimental neutron dosimetry in mixed beam environment, including photon and neutron, the Monte Carlo (MC) simulation is a gold standard method for calculation of photoneutron contaminations. On the other hand, the complexity of treatment head makes the MC simulation more difficult and time-consuming. In this study, the possibility of using a simplified MC model for the simulation of treatment head has been investigated using MCNP4C general purpose MC code. As a part of comparative assessment strategy, the fluence, average energy and dose equivalent of photoneutrons were estimated and compared with other studies for several fields and energies at different points in treatment room and maze. The mean energy of photoneutrons was 0.17, 0.19 and 0.2 MeV at the patient plan for 10, 15 and 18 MeV, respectively. The calculated values differed, respectively, by a factor of 1.4, 0.7 and 0.61 compared with the reported measured data for 10, 15 and 18 MeV. Our simulation results in the maze showed that the neutron dose equivalent is attenuated by a factor of 10 for every 4.6 m of maze length while the related factor from Kersey analytical method is 5 m. The neutron dose equivalent was 4.1 mSv Gy(-1) at the isocentre and decreased to 0.79 mSv Gy(-1) at a distance of 100 cm away from the isocentre for 40 x 40 cm(2). There is good agreement between the data calculated using simplified model in this study and measurements. Considering the reported high uncertainties (up to 50%) in experimental neutron dosimetry, it can be concluded that the simplified model can be used as a useful tool for estimation of photoneutron contamination associated with high-energy photon radiotherapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.