Purpose: Investigations were carried out to assess the use of tape stripping (TS) for the determination of bioequivalence of topical products containing 1% clotrimazole. Methods: The study design involved the establishment of an appropriate application time, which was determined by conducting a dose duration study. Subsequently, two bioequivalence studies were conducted: i) using the brand (Canesten Topical - 1% clotrimazole cream) as both the test and the reference product and ii) comparing Canesten cream with a gel product containing the same concentration of clotrimazole (1%). Each tape strip was individually analyzed for clotrimazole content using an HPLC method and Transepidermal Water Loss (TEWL) measurements were used to normalize the stratum corneum thicknesses between subjects. Results: The results of the TS investigations showed that, if the study is sufficiently powered, tape stripping may be used to determine bioequivalence according to the conventional bioequivalence limits of 0.8–1.25, as well as detect formulation differences between different clotrimazole products. Conclusions: The data from this study provided compelling evidence that tape stripping has the necessary attributes and potential to be used as a tool for the bioequivalence assessment of topical clotrimazole and/or other topical formulations, thereby circumventing the need to undertake expensive and time-consuming clinical trials for such products.
This article is open to POST-PUBLICATION REVIEW. Registered readers (see “For Readers”) may comment by clicking on ABSTRACT on the issue’s contents page.
-Purpose: A draft guidance on tape stripping for assessing the bioavailability/bioequivalence of topical formulations was issued by the United States Food and Drug Administration in 1998 but has since been withdrawn. This was due to problems associated with the method and also inconsistencies and variability in the resulting data. The purpose of this study was to re-visit the tape stripping technique, incorporate refinements to reduce variability and validate the method using bioequivalence data obtained from the assessment of a topical corticosteroid cream containing 0.05% clobetasol propionate using the human skin blanching assay. Methods: A pilot tape stripping study was conducted to establish the variability of the formulations.The bioequivalence of two different commercially available clobetasol propionate cream formulations and a clobetasol propionate ointment formulation were subsequently investigated using the tape stripping method. Results: The data from the pilot tape stripping study correlated well with data from the human skin blanching assay. A subsequent pivotal tape stripping study confirmed bioequivalence between the two cream formulations whereas bio-inequivalence was demonstrated between the cream and ointment formulations. Conclusions: These studies show that the results from tape stripping concur with data from the human skin blanching assay and demonstrate the potential of a well-controlled tape stripping study as an option for the assessment of bioequivalence of topical corticosteroid formulations.
_______________________________________________________________________________________
Dermal microdialysis was used to assess the bioavailability of a topical corticosteroid, clobetasol propionate, following application onto the skin of human subjects. The penetration of clobetasol propionate from a 4% m/v ethanolic solution applied onto 4 sites on one forearm of healthy human volunteers was studied. A lipid emulsion, Intralipid®, was used as the perfusate and linear microdialysis probes with a 2-kDa cutoff were inserted intradermally at the designated sites. The results indicated that Intralipid could be used as a suitable perfusate for in vivo microdialysis of this lipophilic drug of interest. Furthermore, the study clearly demonstrated the application of dermal microdialysis as a valuable tool to assess the bioavailability/bioequivalence of clobetasol propionate penetration into the skin following topical application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.