Coimbra, PortugalPurpose: Sudden cardiac death is an important cause of mortality. Fifteen percent of cases occur without structural heart disease, and most of these events are attributed to inherited cardiac channelopathies (ICCh). Despite the increasing prevalence of this entity, the ideal treatment is not yet defined and the current guidelines are mainly based on expert consensus. Our aim was to evaluate the rate of appropriate (shock and antitachycardia pacing (ATP)) and inappropriate therapy in ICCh patients with implantable cardioverter -defibrillator (ICD) in order to access the value of its implantation in a real world population. Methods: Retrospective study of 37 ICCh patients (46 + 15 years old, 73% male gender) with ICD (54% Brugada syndrome [BrS], 30% idiopathic ventricular fibrillation [IFV], 11% catecholaminergic ventricular tachycardia [CTV] and 5% long QT syndrome [LQTS]). Structural heart disease was excluded in all patients. Patients were under optimized antiarrhythmic treatment and ICD implantation was decided according to the current international guidelines. A clinical follow-up concerning the rate of appropriate/ inappropriate ICD therapies and mortality was done (49 months [1-198]). Results: History of syncope was present in most of the patients (73%) and 14% had a documented episode of ventricular tachycardia (3% sustained and 11% nonsustained). Thirty-one percent of patients had family history of sudden cardiac death and the genetic study was performed in 30% of them (82% BrS and 18% CTV), with pathogenic mutation identification in only one patient (SCN5A). In 51% of patients (84% BrS, 11% CVT, 5% LQTS) the ICD was implanted in primary prevention (42% history of syncope, 42% induction of ventricular arrhythmia in the electrophysiology study and 16% family history of sudden cardiac death in patients with LQTS and CVT). In the remaining 49% patients (61% IVF, 22% BrS, 11% CVT, 6% LQTS) the ICD was implanted in secondary prevention (all of them resuscitated of sudden cardiac death). Ventricular dysrhythmia was identified in 43% of individuals during follow-up (19% nonsustained VT, 19% sustained VT and 5% ventricular fibrillation); appropriated ICD therapies were detected in 22% of patients (11% appropriated shock [5.5% 3 or more shocks; 2.7% BrS, 2.7% CVT, 2.7% LQTS and 2.7% IVF]; 19% ATP). In 38% of patients with appropriated therapies, the ICD have been implanted in primary prevention. Two inappropriate shocks were observed (one due to atrial flutter and the other due to supraventricular paroxysmal tachycardia). There was no mortality during follow-up. Conclusions: This study reflects a high-risk population, with ICD implantation in secondary prevention in about half of the patients. There was a high incidence of ventricular arrhythmias during follow-up, requiring ICD therapy. There was a high number of therapies in patients that implanted the ICD in primary prevention. Thus, the authors conclude that ICD implantation according to current recommendations (even though based just in exper...
Background:In elderly patients, single chamber pacing may be considered. For sinus rhythm patients, VDD pacemaker (PM), by preserving atrial sensing, is a more physiological mode than VVI devices. This study aims to evaluate the long-term performance of VDD PM in elderly patients with atrioventricular block (AVB). Methods: We conducted a retrospective, observational study of 200 elderly patients (≥75 years) with AVB and normal sinus rhythm who consecutively implanted VDD PM between 2016 and 2018. Baseline clinical characteristics were analyzed, complications related to pacemaker implantation were assessed and a 3-years follow-up (FUP) was made. Results: Mean age was 84 ± 5 years. After 3-years FUP, 90.5% (n = 181) of the patients preserved their original VDD mode. Only 19 patients (9.5%) switched to VVIR mode, 5.5% (n = 11) due to P-wave undersensing and 4% (n = 8) due to permanent AF. Those patients had a less amplitude of sensed P wave at baseline [median value of 1.30 (IQR 0.99-2.0) versus 0.97 (IQR 0.38-1.68), p = 0.04]. One third of the patients died dur-ing the FUP, 89% (n = 58) from non-cardiovascular causes. All-cause, CV, and non-CV mortality did not relate with atrial sensing loss during FUP (p = 0.58, p = 0.38 and p = 0.80, respectively). However, atrial sensing loss during FUP was associated with de novo atrial fibrillation (12.7% vs. 31.6%, p = 0.038). Conclusion:VDD pacing is a reliable pacing modality in elderly patients even in longterm. The majority of VDD-paced elderly patients maintained their original VDD mode program, with good atrial sensing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.