Quality assurance (QA) for radiation therapy (RT) in clinical trials is necessary to ensure treatment is safely and effectively administered. QA assurance requires however substantial human and financial resources, as it has become more comprehensive and labor intensive in recent RT trials. It is presumed that RT deviations decrease therapeutic effectiveness of the studied regimen. This study assesses the impact of RT protocol-deviations on patient's outcome in prospective phase II-III RT trials. PubMed, Medline and Embase identified nine prospective RT trials detailing QA RT violation and patient's outcome. Planned QA analysis was preformed retrospectively and prospectively in eight and one studies, respectively. Non-adherence to protocol-specified RT requirements in prospective trials is frequent: the observed major deviation rates range from 11.8% to 48.0% (mean, 28.1 ± 17.9%). QA RT deviations had a significant impact on the primary study end-point in a majority (62.5%) of studies. The number of patients accrued per center was a significant predictive factor for RT deviations in the largest series. These QA data stemming from prospective clinical trials show undisputedly that non adherence to protocol-specified RT requirements is associated with reduced survival, local control and potentially increased toxicity.
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2 x 2 cm(2)). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not fully taken into account by AAA, and small inhomogeneities may lead to planning errors. Second, AAA and MC were compared for IMRT plans in clinical conditions, i.e., dose calculations in a computed tomography scan of a patient. One ethmoid tumor, one orophaxynx and two lung tumors are presented in this paper. Small differences were found between the dose volume histograms. For instance, a 1.7% difference for the mean planning target volume dose was obtained for the ethmoid case. Since better agreement was achieved for the same plans but in homogeneous conditions, these differences must be attributed to the handling of inhomogeneities by AAA. Therefore, inherent assumptions of the algorithm, principally the assumption of independent depth and lateral directions in the scaling of the kernels, were slightly influencing AAA's validity in inhomogeneities. However, AAA showed a good accuracy overall and a great ability to handle small fields in inhomogeneous media compared to other pencil beam convolution algorithms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.