a b s t r a c tExcess volume isotherms of acetonitrile and methanol sorbed on a C 18 BEH UHPLC packing were determined over a range of pressure, temperature, flow rate and eluent composition. The isotherm measurements were carried out by two independent experimental methods, viz., concentration pulse and tracer pulse chromatographies. Isotherms were measured with both experimental techniques at 30, 45 and 60 • C. The excess isotherms increased with decreasing temperature although the variations were relatively small. Direct comparison of the two experimental techniques showed that the measured void volumes were identical within experimental error. The measured excess volumes by both techniques were comparable with the concentration pulse experiments producing slightly higher excess volume data with highly aqueous eluents. Both experimental techniques show some variations of the retention volumes with sample volume, sample composition, flow rate and column inlet pressure. The results confirmed the validity of both concentration and tracer pulse chromatographies for the determination of column void volumes and the excess volume of eluent taken up by UHPLC packings.
Experimental results for the investigation of chromatographic columns containing two mobile phases are presented. The eluent was composed of mixtures of methanol and carbon dioxide. The column was an uncoated fused-silica-lined stainless steel capillary column. At certain experimental conditions, the eluent divided into two phases, both of which moved through the column. The predominant component of the liquid phase was methanol whereas the gas phase was composed of at least 93 mol % CO2. The columns were studied over a range of feed compositions (45-95 mol % CO2), pressures (61-101 bar), and temperatures (30-100 degrees C). The compositions and densities of each phase were calculated from the Peng-Robinson equation of state. The residence times of the two mobile phases were determined by tracer pulse chromatography. The partition coefficients of a probe solute, benzene, were measured along with the retention times of neon and the total volume of the chromatographic column as a function of temperature, pressure, and stoichiometric feed composition. The calculated column volumes, that is the volume of the liquid and gas, were constant over the full range of feed composition. The partition coefficient of benzene was constant at fixed pressure and temperature, varied logarithmically with density at fixed temperature and feed composition, and displayed a maximum at intermediate temperatures at fixed pressure and feed composition. The measured retention times of neon were consistently equivalent to the calculated residence times of the gas phase, indicating that neon did not dissolve in the liquid phase and could thus serve as an accurate dead time marker. The implementation of chromatography with two mobile phases produces a chromatographic "window". There is a lower limit for the retention volume of all solutes, viz., the residence time of the gas phase, exactly the same as normal chromatography. However, elimination of the stationary phase produces an upper limit to the retention volumes of solutes. This upper limit is the residence time of the liquid phase, so there is a retention window such that tG < or = ti < or = tL for all solutes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.