Process control of dielectric CMP has become more stringent as device dimensions decrease. This study repons on the improvement in process control that was obtained by using an integrated metrology tool, and automated, factory-level, process control algorithms. The control methodology was proven to be capable of handling mUltiple pattern levels, with diff erent pattern densities, on multiple polishers in an advanced-prototype/development fab. The improvement in controland throughput with respect to offline metrology and manual control is presented ..Residual sources of variation are analyzed, and schema for junher improvements in control capability are presented, based on tests conducted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.