With the increasing emphasis on sustainability, more and more environmentally friendly new materials and structures are developed, but they are difficult to be applied in engineering practice due to the lack of mature force resistance models. The design assisted by the testing method proposed by ISO2394:2015 and EN1990:2002 can solve this problem effectively. The aim of this paper was to analyze the characteristics of the method from a mathematical and statistical point of view based on the data and to suggest improvements. The resistance of each concrete member was derived by the design assisted by testing methods. The derivation results showed that the p values, the number of tests n , the coefficient of variation θ , and the coefficient of variation of resistance V R known or unknown have a large impact on the derived results. Also, the derivation by the Bayesian procedure or interval estimation methods might be negative. This indicates that the theory of the method is not rigorous and has some disadvantages.
The in-plane seismic behavior of unreinforced masonry (URM) structures is closely related to the aspect ratio of the wall and vertical load. The purpose of this study was to investigate the difference between the failure mode of the model and the horizontal load using the finite element model (FEM) under the action of aspect ratio (0.50 to 2.00) and vertical load (0.2 MPa to 0.70 MPa). The overall macro model was established using the Abaqus software, and the corresponding simulation was performed. The simulation results indicate that: i) the shear failure and flexural failure were the main failure modes of masonry walls; ii) shear failure could be viewed as the main failure mode of the model when the aspect ratio was less than 1.00; however, the flexural failure was considered to be the main failure mode of the model once the aspect ratio was greater than 1.00; iii) when a vertical load of 0.20 MPa was applied to the model, only flexural failure was observed, regardless of whether the aspect ratio of the model increased or decreased; the flexural shear mixed failure was captured within the range of 0.30 MPa– 0.50 MPa; the shear failure was the main failure mode within the range of 0.60 MPa– 0.70 MPa; and iv) the wall with an aspect ratio less than 1.00 could bear a higher horizontal load, and the increase in vertical load can significantly improve the horizontal load of the wall. In contrast, once the aspect ratio of the wall reaches or exceeds 1.00, the increase in the vertical load has little effect on the increase in the horizontal load of the wall.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.