The thermosyphon is a type of heat exchanger that has been widely used in many applications. The use of thermosyphons has been intensified in recent years, mainly in the manufacture of solar collectors and various industrial activities. A thermosyphon is a vertical sealed tube filled with a working fluid, consisting of, from bottom to top, by an evaporator, an adiabatic section, and a condenser. The study of geyser-boiling phenomena, which occurs inside the thermosyphon is of extreme importance, therefore the experimental analysis of the parameters related to the two-phase flow (liquid-steam), such as void fraction, bubble frequency, bubble velocity, and bubble length are necessary, since these parameters have a significant influence on heat transfer. In this work, a pair of wire mesh sensors was used, a relative innovative technology to obtain experimental values of the reported quantities for measuring these parameters of slug flow in thermosyphons. An experimental setup is assembled and the sensors are coupled to the thermosyphon enabling the development of the experimental procedure. Here is presented an experimental study of a glass thermosyphon instrumented with two Wire-Mesh Sensors, in which the aforementioned slug flow hydrodynamic parameters inherent to the geyser type boiling process are measured. It was measured successfully, as a function of the heat load (110, 120, 130, 140, and 150W), the void fraction (instantly and average), liquid film thickness, translation velocity of the elongated bubbles, lengths of the bubbles, and the liquid slug (displaced by the bubble rise up). It was observed that the higher the heat load, the lower is the bubble translation velocity. For all heat loads, based on the measured length of liquid slug (consequent displacement of liquid volume), caused by bubbles rise from evaporator to condenser, it could be affirmed to some extent that both boiling regime (pool and film) exist in the evaporator. The measured average void fraction (80%) and liquid film thickness (around 2.5mm) during the elongated bubble passages were approximately constant and independent of the heat load.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.