There is evidence from experimental studies that the time interval from the peak to the end of T-wave reflects the transmural dispersion in repolarization (electrical gradient) between myocardial "layers" (epicardial, M-cells, endocardial). Since Congenital Long QT Syndrome (LQTS) is considered to be classical disease or repolarisation abnormalities, we performed the present study to assess the transmural dispersion of repolarization in LQTS patients. The study group consisted of 17 patients: 7 LQTS pts and 10 pts from the control group. In each patient the 24-hour ECG recording was performed on magnetic tape. The interval from the peak to the end of the T-wave (TpTo) was automatically measured by Holter system during every hour as a measure of transmural dispersion of repolarisation. Thereafter the mean TpTo from 24-hours was calculated. In addition the spatial QT dispersion was measured from 12 lead ECG and 3 channel Holter tape as a difference between the shortest and the longest QT interval between leads. The values were compared between groups using the Anova test. TpTo was 79.6 +/- 9.6 ms (72-92 ms) in LQTS group and 62.4 +/- 7.5 ms (51-70) in the control group (p < 0.001). In LQTS group TpTo was significantly longer at night hours 72.5 +/- 2 when compared to day hours 87.4 +/- 8 (p < 0.01). The spatial QT dispersion was significantly higher in LQTS patients when compared to control, both in 12-lead standard and Holter ECG. Congenital long QT syndrome is associated with increase in both transmural and spatial dispersion of repolarization. The extent of prolongation of the terminal portion of QT in patients with congenital long QT syndrome is greater at night sleep hours compared to daily activity.
and the §Central Military Hospital Warsaw, Poland LUBINSKI, A., ET AL.: The Terminal Portion of the T Wave: A New Electrocardiographic Marker of Risk of Ventricular Arrhythmias. Experimental studies have shown that transmural dispersion of repolarization (DoR), defined as the difference in action potential duration between mid-myocardial M-cells, epicardial, and endocardial cells is reflected in the duration of the terminal portion of the T wave (TpTe) on the surface ECG. Since DoR is an important factor associated with the propensity for reentrant arrhyth mias, this study examined if TpTe may serve as a marker of risk of ventricular arrhythmias. Data from 18 patients with coronary artery disease and inducible sustained ventricular tachycardia (VT group) were compared with those of 16 survivors of myocardial infarction without inducible VT (control group). TpTe was automatically measured in each beat of 24-hour ECG recordings, and programmed ventricular stim ulation was performed in the antiarrhythmic drug-free state. TpTe was expressed as the absolute interval in milliseconds, and relative to the duration ofQTe (TpTe/QTe X 100%). TpTe duration was 74 ± 14 ms in the VT group versus 63 ± 16 ms in the control group (P < 0.004). The TpTe interval expressed as a per cent of the QT interval was 21 ± 4% in the VT group versus 17 ± 3% in the control group (P = 0.02). In patients with coronary artery disease, TpTe was longer in patients with, versus without, inducible VT. The results of this study support the hypothesis that TpTe reflects transmural dispersion of repolarization. (PACE 2000; 23[Pt. II]-.1957-1959 ventricular arrhythmias, dispersion of repolarization, T wave
For several years, we have observed the dynamic development of technologies that allow patients to access medical care from the comfort of their homes, without direct contact with the doctor. Innovative solutions based on telemedicine improve care coordination and communication among clinicians, patients, and their families, as well as increases patients' security and gives them greater independence, thus eliminating health care inequalities. The rapidly growth of telemedicine and the adoption of new technologies in clinical practice is also observed in Poland. Crucial moment for the telemedicine facilitation process in our country was Baltic Declaration approved by Minister of Health in 2015, as well as the Medical Profession Amendment Act and remote medical care admission. Since then, as part of the work of the Information Technology and Telemedicine Committee of the Polish Cardiac Society and the Telemedical Working Group, important steps have been taken to implement a telemedicine solutions in the Polish healthcare system, resulting in improved quality and efficiency of this system. The presented document reflects the above actions and encompasses following issues: available telemedicine solutions in the world, analysis of their effectiveness based on clinical trials, funding opportunities, legal status and development prospects telecardiology in Poland.
A b s t r a c tBackground: Temporary atrioventricular (AV) conduction disturbances are a common complication following cardiac surgery, especially involving the aortic valve. Permanent complete AV block is a serious and rare complication. Its prevalence has been estimated at 3-6% of all patients undergoing aortic valve replacement. Identification of factors that affect the occurrence of complete AV block requiring permanent pacemaker implantation might help reduce the risk of this problem in the future. Aim:To evaluate clinical, anatomical and surgical factors that might affect occurrence of complete AV, resulting in the need for permanent pacemaker implantation. Methods:In our prospective study, we analysed clinical data of consecutive 159 patients operated due to isolated aortic valve disease between February 2011 and March 2012. Patients with a pacemaker implanted before that time were excluded from the study. The main indication for surgery was aortic stenosis (n = 114, 71.7%). Infectious endocarditis was an indication in 6 (3.8%) cases. Mean patient age was 65.3 ± 11.4 years, and the proportion of males to females was 56.6%/43.4%. Overall, 135 (84.9%) patients had sinus rhythm preoperatively. All operations were performed using median sternotomy, cardiopulmonary bypass, and hypothermia at 30-32°C. A biological prosthesis was implanted in 120 (70.4%) patients. Patients who needed an additional procedure such as another valve surgery, aortic surgery or coronary artery bypass grafting were excluded from the study.Results: Permanent pacemaker implantation was required in 11 (6.9%) patients. The pacemaker was implanted after at least 7 days of complete AV block which was then considered permanent. Univariate analysis showed that permanent pacemaker implantation was associated with prolonged cardiopulmonary bypass time, prolonged aortic cross-clamp time, and the occurrence of electrolyte disturbances. Univariate logistic regression revealed that the need for permanent pacemaker implantation depended on 5 factors including prolonged cardiopulmonary bypass time, prolonged aortic cross-clamp time, larger size of the implanted valve prosthesis, endocarditis as the indication for surgery, and electrolyte disturbances. In both backward and forward stepwise multivariate regression models, two parameters, prolonged aortic cross-clamp time and the presence of electrolyte disturbances, correlated with the occurrence of complete AV block. Conclusions:Permanent complete AV block is a serious complication after aortic valve surgery. Of all analysed clinical, anatomical and surgical factors, prolonged cardiopulmonary bypass time, prolonged aortic cross-clamp time, larger size of the implanted valve prosthesis, endocarditis as the indication for surgery, and electrolyte disturbances were found to be statistically significant predictors of permanent pacemaker implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.