Background Collagenase clostridium histolyticum-aaes (CCH-aaes) is approved for the treatment of moderate-to-severe buttock cellulite in adult women. Objectives To report on real-world experience with CCH-aaes in the treatment of buttock and thigh cellulite. Methods Retrospective analysis of medical records from a single treatment center. Results The population comprised 28 consecutively treated women; mean age was 40.5 years (range, 23-56 years) and mean body mass index was 25.9 kg/m2 (range, 19.6-41.0 kg/m2). Treatment areas were buttocks only (78.6% of patients), thighs only (10.7%), or both buttocks and thighs (10.7%). Most patients (89.3%) were treated in 2 areas (buttocks or thighs) at each visit; however, 3 patients were treated in 4 areas. At each session, the CCH-aaes dose was 0.07 mg per dimple (0.3 mL of 0.23 mg/mL for buttock cellulite; 1.5 mL of 0.046 mg/mL for thigh cellulite). The mean number of treatment sessions was 2.6 (range, 1-4) for buttock cellulite and 2.5 (range 1-3) for thigh cellulite. The mean number of dimples treated was 11.5 (range, 3-17) per buttock, 11.0 (range, 1-14) per thigh, and 23.4 (range, 8-32) overall per treatment session. Injection site–related adverse events of special interest were experienced by all 28 patients: bruising (100%), edema (96.4%), tenderness (85.7%), nodules (39.3%), pruritus (32.1%), and hyperpigmentation indicative of hemosiderin staining (7.1%). Mean duration of injection-site bruising was 8.8 days (range, 2-15 days). Conclusions CCH-aaes is an effective, well-tolerated, minimally invasive treatment option for buttock and thigh cellulite in women.
Background The role of ATX-101 in submental fat reduction has been well documented; however, its applicability across multiple anatomic areas is to be explored. Objectives To describe the experience with ATX-101 subcutaneous injections for body and jawline contouring and evaluate its safety in the real world. Methods This single-arm, single-center observational study included 201 patients who underwent injection adipocytolysis with ATX-101 (area-adjusted dose of 2 mg/cm2) in the jowl, abdomen (upper/lower), thigh (inner/outer/banana roll), arm, anterior periaxillary fat, back (lower/upper/nape/lipoma), knee (anterior/medial), chest, and/or neck. The number of treatment sessions, treatment volumes, doses, injections required for each anatomic area, and associated adverse events were recorded. Results The mean number of treatment sessions conducted was 1.8. Multiple sessions were common for the jowl (mean: 2.0 and mean volume administered varied significantly between persons receiving 1 or multiple sessions [P = 0.005]). The mean volume and mean number of injections per session were highest in the chest (84.7 mL and 423.5, respectively) and lowest in the jowl (0.8 mL and 4.6, respectively). The chest (0.2 mL) and nape (0.2 mL) received the highest mean ATX-101 dose per injection site per session, whereas the inner thigh (0.11 mL) and upper back (0.11 mL) received the least. Adverse events observed were localized to the injection site. All patients experienced edema after each session, whereas numbness, tenderness, bruising, and paresis were experienced by 99.6%, 94.2%, 33.1%, and 2.6% of patients, respectively. Alopecia was not observed. Conclusions ATX-101 was well tolerated for body and jawline contouring.
Background The subdermal application of energy using a helium-based plasma radiofrequency (RF) device has been shown to improve skin laxity. Helium-based plasma RF technology (Renuvion; Apyx Medical, Clearwater, FL) utilizes RF to ionize helium into an electrically conductive plasma capable of coagulating and contracting soft tissue with high precision and minimal thermal spread. This study provides information on the early use of the new generation of electrosurgical generator (APYX-RS3) containing a feature that allows for quantification of the amount of energy delivered to tissue during treatments. Objective To collate procedure details, treatment settings, and safety data in patients treated with a helium-based plasma device for soft tissue coagulation. Methods A retrospective review was conducted of patients aged ≥18 years who underwent treatment with a helium-based plasma RF device (Renuvion; Apyx Medical, Clearwater, FL) for soft tissue coagulation. Demographic data, procedure details, and adverse events were collected. Results Chart review identified 47 patients with an average age of 45 years and an average BMI of 25.8 kg/m². The amount of energy (J) delivered per treatment area was greatest for abdomen, buttocks, and thighs, with an average of 13.7 kJ, 13.5 kJ, and 10.6 kJ, respectively. No serious, unexpected, or device-related AEs were reported. Conclusions The use of the generator that quantifies the energy (joules) being applied during the procedure, allows the provider to understand and optimize their energy usage. While further research is needed to establish the safety and efficacy of the device for skin tightening, this study provides important information regarding energy application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.