In the 1990s, metered dose inhalers (MDIs) containing chlorofluorocarbons were replaced with dry-powder inhalers (DPIs) and MDIs containing hydrofluorocarbons (HFCs). While HFCs are not ozone depleting, they are potent greenhouse gases. Annual carbon footprint (CO2e), per patient were 17 kg for Relvar-Ellipta/Ventolin-Accuhaler; and 439 kg for Seretide-Evohaler/Ventolin-Evohaler. In 2017, 70% of all inhalers sold in England were MDI, versus 13% in Sweden. Applying the Swedish DPI and MDI distribution to England would result in an annual reduction of 550 kt CO2e. The lower carbon footprint of DPIs should be considered alongside other factors when choosing inhalation devices.
BackgroundChronic obstructive pulmonary disease (COPD) is characterized by inflammation and remodeling of the lungs. This results in alterations in extracellular matrix (ECM) and structural changes leading to airflow obstruction. We studied the expression of tenascin-C (Tn-C) and alpha smooth muscle actin (α-SMA), which act as a marker of myofibroblasts, in large airways from COPD patients. Our aim was to elucidate whether this expression correlated with smoking or with disease development.MethodsBronchoscopy was performed on 20 COPD patients (mean age 56 years; range 39-61; FEV1/FVC < 70% and FEV1 median 53% (range 33-69) of predicted). Age and smoking matched smokers (S) without COPD (n = 13) and age matched non-smokers (NS) (n = 14) served as controls. Bronchial mucosal biopsies were analyzed by immunohistochemistry. The distribution of Tn-C expression was assessed and graded in three levels, and the number of spindle shaped cells staining positive for α-SMA were counted.ResultsBiopsies from COPD patients had more (P < 0.001) Tn-C expression than the two control groups. A significantly (P < 0.05) increased number of spindle shaped cells expressing α-SMA was observed in COPD patients compared with the controls. Smokers and nonsmokers did not differ in this respect. The expression of Tn-C correlated positively (P < 0.001) to the number of α-SMA positive cells.ConclusionsWe demonstrate increased expression of Tn-C and α-SMA positive cells in the large airways in COPD. This was not associated to smoking per se, but to the presence of airway obstruction. Our findings add new information regarding remodeling characteristics and highlight the large airways as a potential site for airways obstruction in COPD.
ObjectiveTo compare the effects of switching from a pressurised metered dose inhaler (pMDI)-based to a dry powder inhaler (DPI)-based maintenance therapy versus continued usual care on greenhouse gas emissions (carbon dioxide equivalents, CO2e) and asthma control.MethodsThis post-hoc analysis was based on a subset of 2236 (53%) patients from the Salford Lung Study in Asthma who at baseline were using a pMDI-based controller therapy. During the study patients were randomised to fluticasone furoate/vilanterol (FF/VI) via the ELLIPTA DPI (switched from pMDI to DPI) (n=1081) or continued their usual care treatment (n=1155), and were managed in conditions close to everyday clinical practice. Annual CO2e (kg) was calculated for the total number of maintenance and rescue inhalers prescribed. Asthma control was assessed by the proportion of ACT responders (composite of ACT total score ≥20 and/or increase from baseline ≥3).ResultsThe groups were well matched for demographic characteristics and baseline Asthma Control Test (ACT) total score (mean age: 49 years; mean ACT score: usual care, 16.6; FF/VI, 16.5). Annual CO2e kg per patient (maintenance plus rescue therapy) was significantly lower with FF/VI DPI treatment (‘switch’ group) than usual care (least squares geometric mean 108 kg (95% CI 102 to 114) vs 240 kg (95% CI 229 to 252), p<0.001). Asthma control was consistently superior over the 12 months in the FF/VI DPI group compared with usual care.ConclusionsPatients switching from a pMDI-based to a DPI-based maintenance therapy more than halved their inhaler carbon footprint without loss of asthma control. The remaining inhaler carbon footprint could be reduced through switches from pMDI to DPI rescue medications or alternative lower-carbon footprint rescue inhalers if available. Asthma control improved in both groups, with greater control demonstrated in those initiated on FF/VI DPI.Trial registration numberNCT01706198.
Background and purpose: b2-Adrenoceptor agonists (b2-agonists) are important bronchodilators used in the treatment of asthma and chronic obstructive pulmonary disease. At the molecular level, b2-adrenergic agonist stimulation induces desensitization of the b2-adrenoceptor. In this study, we have examined the relationships between initial effect and subsequent reduction of responsiveness to restimulation for a panel of b2-agonists in cellular and in vitro tissue models. Experimental approach: b2-Adrenoceptor-induced responses and subsequent loss of receptor responsiveness were studied in primary human airway smooth muscle cells and bronchial epithelial cells by measuring cAMP production. Receptor responsiveness was compared at equi-effective concentrations, either after continuous incubation for 24 h or after a 1 h pulse exposure followed by a 23 h washout. Key findings were confirmed in guinea pig tracheal preparations in vitro. Key results: There were differences in the reduction of receptor responsiveness in human airway cells and in vitro guinea pig trachea by a panel of b2-agonists. When restimulation occurred immediately after continuous incubation, loss of responsiveness correlated with initial effect for all agonists. After the 1 h pulse exposure, differences between agonists emerged, for example isoprenaline and formoterol induced the least reduction of responsiveness. High lipophilicity was, to some extent, predictive of loss of responsiveness, but other factors appeared to be involved in determining the relationships between effect and subsequent loss of responsiveness for individual agonists. Conclusions and implications: There were clear differences in the ability of different b2 agonists to induce loss of receptor responsiveness at equi-effective concentrations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.