Purpose The equivalent square (ES) concept has been used for traditional radiation fields defined by the machine collimating system. For small fields, the concept Sclin was introduced based on measuring dosimetric field width (full‐width half maximum, FWHM) of the cardinal axis of the beam profiles. The pros and cons of this concept are evaluated in small fields and compared with the traditional ES using area and perimeter (4A/P) method based on geometric field size settings, for example, light field settings. Methods One hundred thirty‐seven square and rectangular fields from 5–50 mm with every possible permutation (keeping one jaw fixed and varying other jaw from 5 to 50 mm) were utilized to measure FWHM for the validation of Sclin. Using a microSilicon detector and a scanning water tank, measurements were performed on an Elekta (Versa) machine with Agility head and a Varian TrueBeam with different MLC/Jaw design to evaluate the Sclin concept and to understand the effect of exchange factor in small fields. Field output factors were also measured for all 137 fields. Results The data fitting for fields ranging from 5–50 mm between the traditional 4A/P method and Sclin shows differences and indicates a linear relationship with distinct separation of slope for Elekta and Varian machines. For Elekta Agility machine ES based on 4A/P < Sclin and for the VarianTrueBeam 4A/P > Sclin for square fields. Our measured data show that both methods are equally valid but does vary by the machine design. The field output factor is dependent on the elongation factor as well as machine design. For fields with sides ≥10 mm, the exchange factor is nearly identical in both machines with magnitude up to 4%, which is close to measurement uncertainty (±3%), but for small fields (< 10 mm), the Elekta machine has higher exchange factors compared to the Varian machine. Conclusion The results demonstrate that the two concepts for defining equivalent field (Sclin and 4A/P) are equivalent and can be directly related through an empirical equation. This study confirms that 4A/P is still valid for small fields except for very small fields (≤10 mm) where source occlusion is a dominating factor. The Sclin method is potentially sensitive to measurement uncertainty due to measurement of FWHM which is machine‐, detector‐ and user‐dependent, while the 4A/P method relies mainly on geometry of the machine and has less dependency on type of machine, detector, and user. The exchange factors are comparable for both types of machines. The conclusion is based on data from an Elekta with Agility head and a Varian TrueBeam machine that may have potential for bias due to light field/collimator set up and alignment. Care should be taken in extrapolating these data to any other machine.
Gas turbine compressor discs are highly stressed components as they rotate at high speed. Bore region of the disc is the most critical region because any failure at the bore would lead to catastrophic failure of entire gas turbine. Engine start-up and shutdown, as well as major throttle excursions during operation, induce cyclic tensile stresses in this region. These cyclic tensile stresses can exceed yield strength of the material and can thus lead to low cycle fatigue failure. Hence, there is a strong need to enhance fatigue and fracture life of the bore region in order to meet the growing design life requirements. In the present work, method of autofrettage to reduce tensile stresses at bore region has been evaluated. In this case, pre-spin has been used to induce compressive pre-stresses in the bore region. A typical gas turbine compressor rotor forward stage disc was modeled based on design parameters available in literature. Analysis was carried out in 2 stages — non-linear structural analysis of pre-spin to induce compressive stresses and then with operation load to evaluate the effect of pre-stress on stresses and fatigue life in operational conditions in the bore region. Stress intensity factor, KI at the bore region was used to calculate fracture life using LEFM methodology. Comparison of the results for post-spin life with that of the baseline showed 3 times increases in fatigue and 75% increase in fracture life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.