Background:The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus. Methods: The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable collamer lens (ICL) (STAAR Surgical Inc.) to correct refractive error. The outcome was evaluated over six months. There was a change in manifest refraction of 0.09 Ϯ 0.21 (ranging from -0.25 to +0.75) from one week to six months after the surgery. Conclusion:The clinical outcomes of the current study demonstrate the safety, efficacy and predictability of toric implantable collamer lens in the correction of myopia and myopic astigmatism associated with keratoconus. The patients' refractions achieved early stability and remained stable during the course of the study.
Background:The purpose of this study was to determine the predictive value of flash visual-evoked potentials (VEP), relative afferent pupillary defect, and presence of orbital fractures in patients with traumatic optic neuropathy.Methods:A prospective study was conducted in 15 patients with indirect traumatic optic neuropathy. All patients underwent a thorough ophthalmic examination. Initial visual acuity, final visual acuity, and relative afferent pupillary defect were determined, and visual acuity was converted into logMAR units. We performed flash VEP and an orbital computed tomography scan in all patients.Results:There was a good correlation between relative afferent pupillary defect and final visual acuity (r = −0.83), and better initial visual acuity could predict better final visual acuity (r = 0.92). According to findings from flash VEP parameters, there was a relationship between final visual acuity and amplitude ratio of the wave (r = 0.59) and latency ratio of the wave (r = −0.61). Neither primary visual acuity nor final visual acuity was related to the presence of orbital fractures in the orbital CT scan.Conclusion:Patients with traumatic optic neuropathy often present with severe vision loss. Flash VEP, poor initial visual acuity, and higher grade of relative afferent pupillary defect could predict final visual acuity in these patients. Presence of orbital fracture was not a predictive factor for primary visual acuity or final visual acuity.
Purpose:To evaluate the long-term visual outcomes and complications of the piggyback intraocular lens (IOL) implantation compared to aphakia for infantile cataract.Patients and Methods:In a comparative study from 1998 to 2007, piggyback IOL implantation (piggyback IOL group) was performed for 14 infants (23 eyes) with infantile cataract and 20 infants (32 eyes) who were aphakic (aphakia group) after infantile cataract surgery. Data were collected on logMAR visual acuity, and postoperative complications over a mean follow-up time of 6.2 ± 1.7 years and 5.8 ± 1.7 years.Results:The mean age at surgery was 7.5 ± 0.6 months and 6.0 ± 3.3 months for the piggyback and the aphakic group respectively (P > 0.05). At the last follow-up visit, visual acuity was 0.85 ± 0.73 (median = 0.70, interquartile range = 0.3–1.32) in the piggyback IOL group and 0.89 ± 0.56 (median = 0.86, interquartile range = 0.50–1.24) in the aphakic group (P > 0.05). There was a positive relationship between age and visual outcomes in the aphakic group (r = 0.4, P = 0.04) but not in the piggyback IOL group (P = 0.48). There was no significant difference between the mean myopic shift in the piggyback IOL group (∑5.28 ± 1.06 D) and the aphakic group (∑5.10 ± 1.02 D) (P > 0.05). The incidence of reoperation due to complications in piggyback IOL group was higher than aphakic group (%48 vs. %16, respectively, P ≤ 0.01). However, in patients older than 6 months, this risk was not significantly different compared to the aphakic group.Conclusions:Although piggyback IOL implantation for infantile cataract is optically acceptable as a treatment option, there is no significant difference in visual outcomes compared to aphakia. The incidence in reoperation due to complications in patients aged 6 months or younger is higher than those treated with aphakia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.