This case indicates the diversity of striatal dysfunction induced by hyperglycaemia. For good prognosis of diabetic striatopathy, prompt diagnosis and appropriate treatments are important. Physicians should be aware that this disease can cause various neurological and psychiatric symptoms other than chorea or ballismus.
The purpose of this study was to investigate whether the novel image-based noise reduction software (NRS) improves image quality, and to assess the feasibility of using this software in combination with hybrid iterative reconstruction (IR) in image quality on thin-slice abdominal CT. In this retrospective study, 54 patients who underwent dynamic liver CT between April and July 2017 and had a body mass index higher than 25 kg/m2 were included. Three image sets of each patient were reconstructed as follows: hybrid IR images with 1-mm slice thickness (group A), hybrid IR images with 5-mm slice thickness (group B), and hybrid IR images with 1-mm slice thickness denoised using NRS (group C). The mean image noise and contrast-to-noise ratio relative to the muscle of the aorta and liver were assessed. Subjective image quality was evaluated by two radiologists for sharpness, noise, contrast, and overall quality using 5-point scales. The mean image noise was significantly lower in group C than in group A (p < 0.01), but no significant difference was observed between groups B and C. The contrast-to-noise ratio was significantly higher in group C than in group A (p < 0.01 and p = 0.01, respectively). Subjective image quality was also significantly higher in group C than in group A (p < 0.01), in terms of noise and overall quality, but not in terms of sharpness and contrast (p = 0.65 and 0.07, respectively). The contrast of images in group C was greater than that in group A, but this difference was not significant. Compared with hybrid IR alone, the novel NRS combined with a hybrid IR could result in significant noise reduction without sacrificing image quality on CT. This combined approach will likely be particularly useful for thin-slice abdominal CT examinations of overweight patients.
Background
The penumbra occlusion device (POD) is a recently developed metallic coil with a unique anchor segment. The purpose of this study was to investigate the anchoring function of the POD for embolization of medium-sized vessels in detail.
Materials and methods
We reviewed a series of cases of proximal embolization of medium-sized vessels in which the POD was used. Endovascular outcomes and complications were assessed. The distance between the distal end of the first-indwelled POD and the microcatheter tip was defined as the “landing distance,” and this was also evaluated via fluoroscopic analysis.
Results
POD deployment was successful in 17 of 18 patients. The median landing distance was 9.6 mm, and no distal POD migration was observed after the formation of anchor loops.
Conclusions
The specific anchoring function of the POD enables effective proximal occlusion of medium-sized vessels.
The title salt, [CoBr(C11H27N5)]Br2·2H2O, contains a complex cation with mirror symmetry and two Br− counter-anions that are likewise located on the mirror plane. The central CoIII atom of the complex cation has one Br− ion in an axial position, one N atom of the pentadentate macrocyclic ligand in the other axial position and four N atoms of the ligand in equatorial positions, defining a distorted octahedral coordination geometry. The macrocyclic ligand is coordinated to the CoIII atom within a 5, 6, 5 arrangement of chelate rings in the equatorial plane of the four N atoms. Due to symmetry, the configuration of the chiral N atoms is 1RS, 4SR, 10RS, 13SR. In the crystal, N—H⋯Br, O—H⋯Br and N—H⋯O hydrogen bonds between the complex cation, anions and lattice water molecules generate a three-dimensional network.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.