New deep brain stimulation (DBS) electrode designs offer operation in voltage and current mode and capability to steer the electric field (EF). The aim of the study was to compare the EF distributions of four DBS leads at equivalent amplitudes (3 V and 3.4 mA). Finite element method (FEM) simulations (n = 38) around cylindrical contacts (leads 3389, 6148) or equivalent contact configurations (leads 6180, SureStim1) were performed using homogeneous and patient-specific (heterogeneous) brain tissue models. Steering effects of 6180 and SureStim1 were compared with symmetric stimulation fields. To make relative comparisons between simulations, an EF isolevel of 0.2 V/mm was chosen based on neuron model simulations (n = 832) applied before EF visualization and comparisons. The simulations show that the EF distribution is largely influenced by the heterogeneity of the tissue, and the operating mode. Equivalent contact configurations result in similar EF distributions. In steering configurations, larger EF volumes were achieved in current mode using equivalent amplitudes. The methodology was demonstrated in a patient-specific simulation around the zona incerta and a “virtual” ventral intermediate nucleus target. In conclusion, lead design differences are enhanced when using patient-specific tissue models and current stimulation mode.
Computational models for activation assessment in deep brain stimulation (DBS) are commonly based on neuronal cable equations. The aim was to systematically compare the activation distance between a single cable model implemented in MATLAB, and a well-established double cable model implemented in NEURON. Both models have previously been used for DBS studies. The field distributions generated from a point source and a 3389 DBS lead were applied to the neuron models as input stimuli. Simulations (n=670) were performed with intersecting axon diameters (D) between the models (2.0, 3.0, 5.7, 7.3, 8.7, 10.0 μm), variation in pulse shape and amplitude settings (0 to 5 in increments of 0.5 mA or V) with the single cable model as reference. Both models responded linearly to change of input (point source: 0.93<R 2 <0.99, DBS source: R 2 >0.98), but with a systematic extended activation distance for the single cable model. The difference for a point source ranged from −0.2 mm (D=2.0 μm) to −1.1 mm (D=5.7 μm). For the DBS lead a D=3.2 μm agreed with the commonly used double cable simulations D =5.7 μm in voltage mode. Possible reasons for the deviation at larger axons are the internodal length, the ion channel selection and physiological data behind the models. The single cable model covers a continuous range of small axon diameters and calculated the internodal length for each iteration, whereas the double cable models uses fixed defined axon diameters and tabulated data for the internodal length. Despite different implementations and model complexities, both models present similar sensitivity to pulse shape, amplitude and axon diameter. With awareness of the strength and weakness both models can be used to extract activation distance used to relate a specific electric field isolevel and thus estimate the volume of tissue activated in DBS simulation studies.
No abstract
The objective was to develop a physical action potential generator (Paxon) with the ability to generate a stable, repeatable, programmable, and physiological-like action potential. The Paxon has an equivalent of 40 nodes of Ranvier that were mimicked using resin embedded gold wires (Ø = 20 μm). These nodes were software controlled and the action potentials were initiated by a start trigger. Clinically used Ag-AgCl electrodes were coupled to the Paxon for functional testing. The Paxon's action potential parameters were tunable using a second order mathematical equation to generate physiologically relevant output, which was accomplished by varying the number of nodes involved (1–40 in incremental steps of 1) and the node drive potential (0–2.8 V in 0.7 mV steps), while keeping a fixed inter-nodal timing and test electrode configuration. A system noise floor of 0.07 ± 0.01 μV was calculated over 50 runs. A differential test electrode recorded a peak positive amplitude of 1.5 ± 0.05 mV (gain of 40x) at time 196.4 ± 0.06 ms, including a post trigger delay. The Paxon's programmable action potential like signal has the possibility to be used as a validation test platform for medical surface electrodes and their attached systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.