The aim of this study was to assess in-stent restenosis (ISR) of coronary artery for patients with CoCr stent using subtraction coronary computed tomography angiography (CCTA) with one-breath-hold scan on 320-row area detector CT, invasive coronary angiography (ICA) as clinical standard. Patients who were referred for CCTA from January 2020 to May 2021 were retrospectively analyzed. Pre-contrast and CCTA was performed with dedicated one-breath-hold subtraction scan protocol and post processing to get subtracted-CCTA image without stent. Subjective image qualities and diagnosable rate were analyzed for CCTA and subtracted-CCTA respectively. The ISR degree of each stent was evaluated both on CCTA and subtracted-CCTA images. The receiver-operating characteristic curve with sensitivity, specificity, accuracy of CCTA, and subtracted-CCTA in the diagnosis of ISR were calculated with ICA as reference. Forty patients with 85 CoCr coronary stents of 3 to 3.5 mm diameter with ICA confirmation within 1 month were finally included. Subtracted-CCTA showed more diagnosable segments of stent (91.76% [78/85]) than those of CCTA (50.59% [43/85]) ( P < .001). The subjective image quality score of CCTA was 2.23 ± 1.32 while 3.41 ± 0.90 on subtracted-CCTA ( P < .001). Both subtracted-CCTA and CCTA showed high consistency with ICA (Kappa = 0.795 and 0.918 respectively). The area under the curve was 0.607 for CCTA and 0.757 for subtracted-CCTA ( P < .001) for stent based diagnose, respectively. The sensitivity, specificity, accuracy of CCTA, and subtracted-CCTA were 90.0%, 97.0%, 95.3%, and 87.5%, 100.0%, 97.43%, respectively. Subtracted-CCTA showed improved diagnose performance for ISR, which potentially reduce further follow-up ICA procedures for patients with CoCr stents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.