This study aimed to analyze the functional and radiological outcomes of lumbar decompression in patients with degenerative lumbar scoliosis (DLS). Overview of Literature: Patients with DLS have symptoms related to lumbar canal stenosis (LCS) and those due to compensated spinal imbalance. Whether the deformity is the cause of pain or is an adaptive change for the ongoing LCS remains debatable. The extensive surgery for deformity correction along with spinal fusion is reported to have high perioperative morbidity and complication rate. Methods: This retrospective analysis involved 51 patients who underwent lumbar decompression for LCS associated with DLS from October 2006 to October 2016. The magnitude of the curve was determined using Cobb's angle and lumbar lordosis (D12-S1) on the preoperative and final follow-up, respectively. The Visual Analog Scale (VAS) and modified Oswestry Disability Index (mODI) scores at the preoperative and final follow-up indicated the functional outcome. Statistical analyses were performed using Student t-test. Results: All 51 patients were included in the statistical analyses. The mean patient age at presentation was 63.88±7.21 years. The average follow-up duration was 48±18.10 months. The average change in the Cobb's angle at the final follow-up was statistically insignificant (1°±1.5°, p=0.924; 20.8°±5.1° vs. 21.9°±5.72°). The mean change in lumbar lordosis at the final follow-up was statistically insignificant (3.29°±1.56°, p=0.328; 30.2°±7.9° vs. 27.5°±7.1°). There was statistically insignificant worsening in the back VAS scores at the final follow-up (4.9±1.9 vs. 6.0±1.2, p=0.07). There was statistically significant improvement in the leg pain component of the VAS score at the final follow-up (5.8±1.05 vs. 2.6±1.2, p<0.001). There was statistically significant improvement in the mODI scores at the final follow-up (p<0.001). Conclusions: Lumbar decompression in DLS is associated with good functional outcome, especially when the symptoms are related to LCS. Curve progression following lumbar decompression is very less at mid-term and is similar to that in the natural course of the disease.
Study design
A cross-sectional retrospective Level 3 study.
Objective
To study the serum levels of Titanium and Aluminium ions in patients operated using the magnetically controlled growing rod (MCGR) system.
Summary of background data
14 consecutive patients of early onset scoliosis with varying etiology managed with MCGR system with a minimum follow-up of 24 months were selected for the study. The group consisted of two boys (14.3%) and 12 girls (85.7%). The average age of the patients at the time of surgery was 10.4 years (5–15 years). The average period of follow-up was 43.7 months (28–79 months). After informed consent of the subjects and their caretakers, serum levels of titanium and aluminium were measured. These levels were then assessed with regards to the number of screws used, number of distractions and complications.
Methods
The concentration of titanium and aluminium ions in the serum was measured using high resolution inductively coupled plasma mass spectrometry.
Results
For the sake of ease of assessment, patients were divided into three etiology-based groups—idiopathic (n = 6), neuromuscular (n = 2) and syndromic (n = 6). The mean serum titanium level was 15.9 μg/L (5.1–28.2 μg/L) while that of aluminium was 0.1 μmol/L (0.1–0.2 μmol/L). Of the 14 patients, 2 (14.2%) patients had mechanical failure (actuator pin dysfunction), 3 (21.4%) had rod breakage requiring revision surgery and one patient (7.1%) had surgical site infection managed with appropriate antibiotics. Patients undergoing revision for rod breakage did not show any metallosis of the tissues during surgery.
Conclusion
Analysis of patients with scoliosis operated using the magnetic growing rod system concludes that it is accompanied by presence of titanium in the blood but whether clinically significant or not needs to be ascertained by comparison of preoperative and postoperative blood concentrations of the titanium ions in individual subjects. The aluminium ion concentration remains within normal limits. Though implant malfunction may raise the titanium levels in the blood, its clinical significance needs to be determined. The aluminium levels are not affected irrespective to the presence or absence of complications. The long-term effects of raised titanium levels in the blood also warrant further prospective studies designed for precise and deeper analyses.
The case report discusses rare occurrence of multiple level fractures of cervical spine following trivial injury to the neck in a patient with osteopetrosis and its treatment with conservative management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.