Chronic pelvic pain (CPP) is a common cause of gynecologic referral. Pelvic congestion syndrome, which is said to occurs due to ovarian vein incompetence, is a recognized cause of CPP. The aim of this paper is to briefly describe the clinical manifestations, and to review the role of diagnostic and interventional radiology in the management of this probably under-diagnosed condition.
We present a case of retrocaval ureter and its MR appearances. This is the first case in reported literature. The findings on i.v. urography are correlated with the MRI findings. So far CT has been the procedure of choice to confirm the diagnosis of retrocaval ureter. However, we believe MRI is likely to replace CT in the diagnosis of retrocaval ureter.
This retrospective analysis showed the use of sorafenib in patients selected according to BCLC staging, and it is the first external validation of early dermatologic adverse events as a predictor of overall survival in patients with advanced hepatocellular carcinoma.
Complex and lengthy interventional radiological techniques have resulted in a number of patients developing skin reactions in recent years. To safeguard against these side effects, we have investigated the degree to which entrance skin dose can be reduced by inserting 0.18 mm and 0.35 mm copper filtration in the incident beam. The potential reduction was measured on a 22 cm water phantom for each of eight models of a fluoroscopy unit. Using the catheter laboratory fluoroscopy unit on which radiofrequency ablations are routinely performed, we assessed the relative effectiveness of adding filtration and increasing the kV:mA ratio. Image quality was subjectively assessed for diagnostic and therapeutic acceptability in two groups of 10 patients undergoing radiofrequency ablations, pacemaker insertions or electrophysiology studies. One of the groups was screened with 0.35 mm copper filtration in place and the other group acted as the control. Maximum patient skin dose proved difficult to measure directly because of the unpredictable dose pattern. This pattern was studied in four patients using a film method in conjunction with thermoluminescent dosemeters. Copper filtration 0.35 mm thick inserted in the beams of the eight fluoroscopy units produced a mean reduction in entrance dose to the phantom of 58% with a mean increase in tube loading of 29%. At 100 kV the increased loading on the X-ray tube was equivalent to increasing the anteroposterior separation of the patient by 2 cm. Measurements on the catheter laboratory unit showed that the tube voltage would need to be raised above the normal diagnostic range to obtain an equivalent entrance dose reduction without the filter. The blackening of films under the patients showed complex patterns, but the estimated skin doses were consistent with those predicted by the phantom experiments. All six cardiologists considered there to be insignificant detriment to image quality in the procedures investigated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.