We evaluated ultrasonic examination as a diagnostic tool for catheter misplacement and pneumothorax after central venous catheter insertion. Physicians in the intensive care unit (ICU) performed the ultrasonic examinations, and the results were compared with those of chest radiography. Eighty-five central venous catheters (70 subclavian and 15 internal jugular) were inserted into 81 patients; 10 misplacements and one pneumothorax occurred. Ultrasonic examination feasibility was 99.6%. The only pneumothorax and all misplacements except one were diagnosed by ultrasound. Taking into consideration misplacements and pneumothorax research, ultrasonic examination did not give any false positive results. The mean time of the entire ultrasonic examination was 6.8 +/- 3.5 min, whereas 80.3 +/- 66.7 min were needed for the radiography (p < 0.0001). This study has suggested that ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is a rapid and accurate method that can be easily performed by ICU physicians.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.