Twelve-month old infants (N ϭ 76) experienced 4 situations of unresponsiveness in which their mothers and a stranger directed positive attention toward a doll or a picture book while they ignored the infant. Infants demonstrated more protest, negative vocalizations and inhibited play during the doll condition, particularly if the doll was held by the mother. Infant contacts with the mother were more frequent when the mother held the doll. Infants' distress during the mother/doll condition was interpreted as jealousy.
Purpose: We present a simple, fast and robust method to optimize both the number and position of catheters in interstitial high dose rate (HDR) brachytherapy, using a modified version of the Centroidal Voronoi Tessellations algorithm. Methods: 8 HDR clinical cases were chosen randomly for both prostate and breast to test our method. The dose distributions were obtained using a research version of IPSA. Clinically relevant dosimetric parameters were computed to evaluate our method and test the robustness. For the prostate, plans generated from our method were compared to the clinical cases with 17 catheters. The efficiency of the algorithm was also tested with breast cases. The robustness of the method to implantation error was evaluated using 100 iterations and an error of 1, 2, 3, or 5 mm to each catheter of the plan. Results: A better or equal prostate V100 was obtained with as few as 12 catheters when compared with the clinical case. Plans with 9 or less catheters would not be clinically acceptable. Plans with 17 catheters were better than the clinical plans with the same number of catheters. The computation time to obtain 10 complete treatment plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. For the breast, on average, the RTOG recommendations would be satisfied with 12 catheters. Plans with 9 or less catheters would not be clinically acceptable in terms of V100, DHI and D90. Implantation errors up to 3 mm were acceptable. Conclusion: We have devised a simple, fast, robust and efficient method to optimize the number and position of catheters in HDR brachytherapy. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real‐time guidance and planning for any interstitial brachytherapy sites. Funding support: CIHR and NSERC
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.