Background Older age is associated with increased severity and death from respiratory infections, including coronavirus disease 2019 (Covid-19). The tuberculosis vaccine Bacille Calmette-Guérin (BCG) may provide heterologous protection against non-tuberculous infections, and has been proposed as a potential preventive strategy against Covid-19. Methods In this multicenter, placebo-controlled trial, we randomly assigned elderly individuals (60 years or older, n=2014) to intracutaneous vaccination with BCG (n=1008) or placebo (n=1006). The primary endpoint was the cumulative incidence of respiratory tract infections that required medical intervention, during 12 months of follow-up. Secondary endpoints included the incidence of Covid-19, and the effect of BCG vaccination on the cellular and humoral immune responses. Results The cumulative incidence of respiratory tract infection requiring medical intervention was 0.029 in the BCG-vaccinated group and 0.024 in the control group (subdistribution hazard ratio [SHR], 1.26; 98.2% confidence interval [CI], 0.65 to 2.44). 51 and 48 individuals tested positive for SARS-CoV-2 by PCR in the BCG and placebo group, respectively (SHR, 1.053; 95% CI, 0.71 to 1.56). No difference was observed in the frequency of adverse events. BCG vaccination was associated with enhanced cytokines responses after influenza, and partially also after SARS-CoV-2 stimulation. In patients diagnosed with Covid-19, antibody responses after infection were significantly stronger if the volunteers had previously received BCG. Conclusions BCG-vaccination had no effect on the incidence of respiratory tract infections, including SARS-CoV-2 infection, in elderly volunteers. However, BCG vaccination improved cytokine responses stimulated by influenza and SARS-CoV-2, and induced stronger antibody titers after Covid-19 infection.
Organs-on-chips are microfluidic cell culture devices created using microchip manufacturing techniques that contain hollow microchannels lined by living cells, which recreate specialized tissue-tissue interfaces, physical microenvironments, and vascular perfusion necessary to recapitulate organ-level physiology in vitro. Here we describe a protocol for fabrication, culture, and operation of a human lung "small airway-on-a-chip," which contains a differentiated, mucociliary bronchiolar epithelium exposed to air and an underlying microvascular endothelium that experiences fluid flow. First, microengineering is used to fabricate a multilayered microfluidic device that contains two parallel elastomeric microchannels separated by a thin rigid porous membrane; this requires less than 1 day to complete. Next, primary human airway bronchiolar epithelial cells isolated from healthy normal donors or patients with respiratory disease are cultured on the porous membrane within one microchannel while lung microvascular endothelial cells are cultured on the opposite side of the same membrane in the second channel to create a mucociliated epithelium-endothelium interface; this process take about 4-6 weeks to complete. Finally, culture medium containing neutrophils isolated from fresh whole human blood are flowed through the microvascular channel of the device to enable real-time analysis of capture and recruitment of circulating leukocytes by endothelium under physiological shear; this step requires less than 1 day to complete. The small airway-on-a-chip represents a new microfluidic tool to model complex and dynamic inflammatory responses of healthy and diseased lungs in vitro.
Purpose Nerve size is a commonly used sonographic parameter when assessing suspected entrapment of the ulnar nerve. We aimed to create a robust set of normal values, based on a critical review of published normal values. Methods We performed a systematic evaluation of studies on normal ulnar nerve sizes, identified in PubMed, Embase, and Cochrane databases. Using meta-analyses, we determined pooled mean cross-sectional area (CSA) values for different anatomical locations of the ulnar nerve throughout the arm. Subgroup analyses were performed for gender, probe frequency, in- or exclusion of diabetic patients, position of the elbow and Asian versus other populations. Results We identified 90 studies of which 77 studies were included for further analyses after quality review, resulting in data from 5772 arms of 3472 participants. Subgroup analyses show lower CSA values at at the wrist crease and proximal to the wrist crease when using low frequency probes (< 15 MHz) and at the wrist crease, proximal to the wrist crease, proximal forearm and the distal upper arm in Asians. CSA values were lower when in flexed position compared to extended position for the cubital tunnel inlet only. No difference was found for gender. Conclusions Our systematic review provides a comprehensive set of normal values at sites along the entire length of the ulnar nerve. This provides a foundation for clinical practise and upon which future studies could be more systematically compared.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.