Water suppliers aim to achieve microbiological stability throughout their supply system by regular monitoring of water quality. Monitoring temporal biomass dynamics at high frequency is time consuming due to the labor-intensive nature and limitations of conventional, cultivation-based detection methods. The goal of this study was to assess the value of new rapid monitoring methods for quantifying and characterizing dynamic fluctuations in bacterial biomass. Using flow cytometry and two precise enzymatic detection methods, bacterial biomass-related parameters were monitored at three riverbank filtration sites. Additionally, the treatment capacity of an ultrafiltration pilot plant was researched using online flow-cytometry. The results provide insights into microbiological quality of treated water and emphasize the value of rapid, easy and sensitive alternatives to traditional bacterial monitoring techniques.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.