The use of grafted trypsin magnetic beads in a microchip for performing protein digestion is described. The PDMS device uses strong magnets to create a magnetic field parallel to the flow with a strong gradient pointing through the center of the chip channel. This allows for the formation of a low-hydrodynamic resistance plug of magnetic trypsin beads that serves as a matrix for protein digestion. This device represents an inexpensive way of fabricating a multi open-tubular-like column with an appropriate pore size for proteins. Kinetics studies of the hydrolysis of a model peptide show a 100-fold increase in digestion speed obtained by the microsystem when compared to a batch wise system. This system also offers the great advantage of easy replacement, as the bead matrix is easily washed out and replaced. High performance and reproducibility for digesting recombinant human growth hormone are confirmed by analysing the digest products in both CE and MALDI-TOF MS. Similar sequence coverage (of about 44%) is obtained from MS analysis of products after 10 minutes on-chip and 4 h with soluble trypsin in bulk.
The preparation of an easily replaceable protease microreactor for micro-chip application is described. Magnetic particles coated with poly(N-isopropylacrylamide), polystyrene, poly(2-hydroxyethyl methacrylate-co-ethylene dimethacrylate), poly(glycidyl methacrylate), [(2-amino-ethyl)hydroxymethylen]biphosphonic acid, or alginic acid with immobilized trypsin were utilized for heterogeneous digestion. The properties were optimized, with the constraint of allowing immobilization in a microchannel by a magnetic field gradient. To obtain the highest digestion efficiency, sub-micrometer spheres were organized by an inhomogeneous external magnetic field perpendicularly to the direction of the channel. Kinetic parameters of the enzyme reactor immobilized in micro-chip capillary (micro-chip immobilized magnetic enzyme reactor (IMER)) were determined. The capability of the proteolytic reactor was demonstrated by five model (glyco)proteins ranging in molecular mass from 4.3 to 150 kDa. Digestion efficiency of proteins in various conformations was investigated using SDS-PAGE, HPCE, RP-HPLC, and MS. The compatibility of the micro-chip IMER system with total and limited proteolysis of high-molecular-weight (glyco)proteins was confirmed. It opens the route to automated, high-throughput proteomic micro-chip devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.