We evaluated an extended time in the microscopic review in samples in which the potential clinical information could be increased with respect to those that could be achieved with the usual laboratory methodologies. We used samples containing nucleated red blood cells in a small amount and cytopenic samples. For these purposes for each peripheral blood smear, the timing of eye-count differential was increased up to 20 min, regardless of the final number of cells which could be counted. In addition, an automated system for digital analysis of peripheral blood smears was employed and the number of cells counted was brought up to 1000 leukocytes. In both manual and automatic light microscopy extended observation, we obtained more diagnostic information in respect to those with routine or standard methods. Both automated and manual increase systems of the timing for microscopic review are useful tools to find diagnostic information that otherwise would be lost using normal and standard procedures. So, these methods should be used especially when there is a higher pre-test probability for discovery of pathological cells.
AimsThe presence of cold agglutinin in blood samples can cause a spontaneous agglutination of red blood cells (RBCs) when low temperature occurs. This phenomenon causes a spurious lowering of RBC count on the automated haematological analysers that are detected by incongruous values (≥370 g/L) of the mean cellular haemoglobi concentration (MCHC). A preheating at 37°C can remove the RBC agglutination generally resulting in a reliable count. It has been reported that the same result can be reached by using the optical reticulocyte (RET) channel of Sysmex analysers where the RBC count is not influenced by the presence of cold agglutinin. This study aims to evaluate these data in a larger population, with regard to environmental conditions on Sysmex analysers. We have also evaluated the influence of different thermal pretreatments on the RBC count.MethodsThis study was performed on 96 remnants of peripheral blood samples (48 with MCHC in normal range and 48 with MCHC>370 g/L) which have been analysed in different preanalytical conditions on the Sysmex analysers.ResultsA preheating of samples at 41°C for 1 min leads to a reversibility of the cold agglutination comparable to the one observed in the RET channel and yields better results compared with 37°C for 2 hours.ConclusionsNone of described procedures assure the complete cold agglutination reversibility in every case. Consequently, since the haematological analysers not yet provide reliable parameters to confirm the complete resolution of agglutination, further verification of RBC count accuracy needs to be performed.
In recent years, several automated analysers that prepare and stain blood smears have been introduced in clinical laboratories. Despite the use of instrumental settings based on physical characteristic of individual samples, traumatic injuries of neutrophil and lymphocytes can be observed. Some samples present a very high percentage of damaged cells, allowing the speculation that a cellular susceptibility may enhance mechanical traumatism. These artefacts can puzzle morphological evaluation in both traditional and digitised microscopy; in addition, unskilled operators can be misled.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.