IntroductionArtificial fog is used in the film, television, and live entertainment industries to enhance lighting, as a visual effect, and to create a specific sense of mood or atmosphere. This study investigated whether the suspension time of respiratory aerosols spiked with tagged DNA tracers would change in the presence of glycerin- or glycol-containing artificial fogs.Methods & MaterialsRespiratory aerosols with tagged DNA tracers were sprayed into a closed environment without and with glycerin- or glycol-containing artificial fog, with air samples taken at regular intervals to determine the decay of tagged DNA tracer over time. The study treatments included Control (no fog), Glycerin Low (3 mg/m3), Glycerin High (∼15 mg/m3), Glycol Low (∼5 mg/m3), and Glycol High (∼40 mg/m3).ResultsAll artificial fog treatments had lower mean log reduction curves compared to the Control treatment. Compared to the Control and Glycerin Low treatments, the differences in mean log reduction for nearly all other artificial fog treatments were statistically significant (p<0.001); the difference between Control and Glycerin Low treatments was not statistically significant (p=0.087). The differences in mean log reduction between treatments using the same artificial fog type were not statistically significant.ConclusionArtificial fog use does not increase suspension time of respiratory aerosols, and therefore does not appear to increase the risk of airborne transmission of diseases from respiratory aerosols, such as COVID-19. Of the two types of artificial fogs investigated, that containing glycol decreased suspension time more than that containing glycerin. In practice, the additional reduction in suspension time provided by the physical interaction of respiratory aerosols with artificial fog does not suggest any practical benefit for using artificial fog as a control measure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.