HighlightsDynamic obstruction of right ventricle outflow tract is a rare hypotension cause.Never described before as cause of hypotension during anesthesia induction.Echocardiography identifies this condition with or without hemodynamic monitoring.Identified dynamic obstruction can be successfully treated with fluid therapy.
BACKGROUND: Recent meta-analyses failed to support the reliability of ultrasound assessment of the inferior vena cava (IVC) to predict fluid responsiveness. However, the techniques utilized were heterogeneous. We hypothesized that the variability of the elliptic section and caliber of the IVC along its course may influence ultrasound evaluation. Therefore, we investigated IVC size and shape at four levels, before and after a fluid challenge. METHODS: Twenty mechanically-ventilated adult patients who received a fluid challenge after cardiac surgery were enrolled. They were regarded as responders if the cardiac index increased more than 15%. Before and after the fluid challenge, IVC anteroposterior (AP) and lateral (LA) diameters, the flat ratio, and the distensibility index were assessed by ultrasound just above the iliac veins, at the confluence of the renal veins, before the confluence of the hepatic veins (where blood flow velocity was also measured), and after it. RESULTS: At all levels, IVC section was elliptical, so that IVC diameters varied between a minimum and a maximum according to the measurement angle. Such interval increased in correspondence of the renal veins, where IVC section was more eccentric. The distensibility index was higher when assessed on AP diameters. After the fluid challenge, nonresponders showed a diffuse increase of AP diameters, whereas responders showed an increase of blood velocity before the confluence of the hepatic veins. CONCLUSIONS: The elliptic section should be considered when assessing IVC size. AP diameters are shorter and more affected by the respiratory cycle. After a fluid challenge, an increase of blood velocity associated with unchanged AP diameters may suggest fluid responsiveness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.