It has recently been demonstrated that superparamagnetic iron oxide nanoparticles can be used as magnetomotive ultrasound contrast agents. A time-varying external magnetic field acts to move the particles and, thus, the nanoparticle-laden tissue. However, the difficulty of distinguishing this magnetomotive motion from undesired movement induced in regions without nanoparticles or other motion artifacts has not been well reported. Using a high-frequency linear-array system, we found that displacements outside nanoparticle-laden regions can be similar in magnitude to those in regions containing nanoparticles. We also found that the displacement outside the nanoparticle regions had a phase shift of approximately π radians relative to that in the nanoparticle regions. To suppress signals arising from undesirable movements, we developed an algorithm based on quadrature detection and phase gating at the precise frequency of nanoparticle displacement. Thus, clutter at other frequencies can be filtered out, and the processed signal can be color-coded and superimposed on the B-mode image. The median signal-to-clutter ratio improvement using the proposed algorithm was 36 dB compared with simply summing the movement energy at all frequencies. This clutter rejection is a crucial step to move magnetomotive ultrasound imaging of nanoparticles toward in vivo investigations.
Current methods for intra-surgical guidance to localize metastases at cancer surgery are based on radioactive tracers that cause logistical challenges. We propose the use of a novel ultrasound-based method, magnetomotive ultrasound (MMUS) imaging that employ a nanoparticle-based contrast agent that also may be used for pre-operative PET/MRI imaging. Since MMUS is radiation free, this eliminates the dependence between pre- and intra-operative imaging and the radiation exposure for the surgical staff. This study investigates a hypothetical clinical scenario of pre-operative PET imaging, combined with intra-operative MMUS imaging, implemented in a sentinel lymph node (SLN) rat model. At one-hour post injection of 68Ga-labelled magnetic nanoparticles, six animals were imaged with combined PET/CT. After two or four days, the same animals were imaged with MMUS. In addition, ex-vivo MRI was used to evaluate the amount of nanoparticles in each single SLN. All SLNs were detectable by PET. Four out of six SLNs could be detected with MMUS, and for these MMUS and MRI measurements were in close agreement. The MRI measurements revealed that the two SLNs undetectable with MMUS contained the lowest nanoparticle concentrations. This study shows that MMUS can complement standard pre-operative imaging by providing bedside real-time images with high spatial resolution.
Detection and removal of sentinel lymph nodes (SLN) is important in the diagnosis and treatment of cancer. The SLN is the first regional lymph node draining the primary tumor, and if the cancer has spread, it is most likely to find metastases in the SLN. In this study, we have for the first time been able to image the very same contrast agent, superparamagnetic iron oxide nanoparticles (SPIO-NPs), in rat SLNs by using both our frequency- and phase-gated magnetomotive ultrasound (MMUS) algorithm and conventional magnetic resonance imaging (MRI); MMUS post mortem, MRI in vivo. For both higher NP-concentration and smaller NPs, we found that the MMUS data showed a larger magnetomotive displacement (1.56 ± 0.43 and 1.94 ± 0.54 times larger, respectively) and that the MR-images were affected to a higher degree. The MMUS displacement also increased with lower excitation frequency (1.95 ± 0.64 times larger for 5 Hz compared with 15 Hz) and higher excitation voltage (2.95 ± 1.44 times larger for 30 V compared with 10 V). The results show that MMUS has potential to be used as bedside guidance during SLN surgery, imaging the same particles that were used in prior staging with other imaging techniques.
The drive to gain a better understanding of how diseases arise and how to provide ever-earlier detection are some of the key factors for the development of molecular imaging. Compared to other imaging modalities ultrasound has not received the same attention for molecular imaging mainly due to its limited contrast resolution, together with contrast agents confined to the intravascular space. To overcome these issues, new nano-sized contrast agents and new ultrasound imaging techniques e.g. photo acoustic imaging, have been developed. Another such imaging technique under development is magnetomotive ultrasound imaging (MMUS). We have previously developed a frequency and phase tracking algorithm which is able to detect superparamagnetic iron oxide nanoparticles (SPIO NPs) using MMUS, where our suggested first clinical application is to detect sentinel lymph nodes (SLNs) in breast cancer surgery. Recently we have shown detection of SPIO laden rat SLNs in situ.Here we present the feasibility of in vivo detection of SLNs in rats. The algorithm clearly pinpoints the NP laden SLN, even in presence of significant artefactual tissue movement. The magnetomotive displacement increased when a higher voltage was applied on the coil creating the magnetic field (e.g. 56.6% increasing the voltage from 20V to 50V). An uneven concentration distribution of NPs in the SLN was found. The maximum magnetomotive displacement difference between two different cross sections in one SLN was 9.76 times. The study also showed that for a higher concentration of NPs a lower magnetic coil excitation voltage could be used in order to create a magnetomotive displacement of a certain magnitude. The result from this in vivo study shows that the method has potential for future clinical use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.