Fifty-five bovine, 50 equine, 60 ovine, and 50 porcine carcasses were sampled in a slaughterhouse in eastern Spain. Two samples were taken from each carcass, one using the excision method and the other using the swabbing method. Four different materials were used for swabbing: cellulose, polyurethane, or viscose sponges, and medical gauze. Samples were collected at the end of the process by four different people before the carcasses were taken to the cooler. The samples were examined for total viable bacteria counts (TVCs) and Enterobacteriaceae counts (ECs). The mean TVC for all species sampled by excision was 4.50 log CFU/cm(2), which was significantly higher than the 3.53 log CFU/cm(2) obtained by swabbing. The TVCs obtained using gauze and the cellulose and polyurethane sponges were significantly higher (P < 0.05) than the corresponding TVCs obtained using viscose sponges. Animal species, the person who collected the samples, and microbiological load also had a significant effect on TVC. ECs were obtained from 82.8% of excision samples, from larger percentages of samples obtained using cellulose or polyurethane sponges or gauze swabs, but from smaller percentages of samples obtained using viscose sponges. The Enterobacteriaceae load significantly influenced the EC. In contrast, animal species and the person who collected the samples had no significant effect. The cellulose sponge, polyurethane sponge, and gauze gave high mean log counts of aerobic bacteria and Enterobacteriaceae, which makes these swab types suitable for use in slaughterhouses for the purpose of assessing production process hygiene.
Samples from 240 carcasses were collected from four animal species (porcine, ovine, bovine and equine). Two samples were taken from each carcass, one using the excision method (EX) and the other the wet-dry swabbing method (SW). Eight areas from each carcass were sampled. Most of the samples obtained by SW revealed total aerobic viable counts (TVC) levels of between 3.1 and 4.0 log CFU cm )2 , while most of the values corresponding to excision were located between 4.1 and 5.0 log CFU cm )2 . Moreover, Enterobacteriaceae (EC) counts were only detected above 3.0 log CFU cm )2 in 0.85% of the carcasses when the samples were collected by swabbing, while the excision method revealed that 13.75% of the carcasses presented EC greater than 3.0 log CFU cm )2 . TVC and EC by EX revealed statistically significant differences compared to SW, while no significant linear relationship was found between carcass surface bacterial counts obtained by SW and EX.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.