Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up of the optical sensor, sensor electronics, and processing block. Also, we show experimental results obtained during the development of the whole NIR transmittance pulse oximetry system along with modifications in the sensor configuration, signal processing algorithm, and calibration procedure. Issues concerning wavelength selection and its implications for the improvement of the transmittance pulse oximetry technique are discussed. The results obtained demonstrate the proposed system's usefulness in monitoring a wide range of oxygen saturation levels.
Photoplethysmography (PPG) is a non-invasive optical technique that can be used to quantify the arterial blood pulse rate. Signal corruption by motion artifacts limits the practical accuracy and applicability of instruments for monitoring pulse rate during intense physical exercise. This study develops and validates an algorithm, which is based on linear filtering and frequency-domain and heuristic analyses, for extracting the heart rate from a PPG signal in the presence of severe motion artifacts. The basis of the hearth beat frequency selection is the observed high harmonic content of movement artifact signals with respect to the PPG-derived heartbeat. The algorithm, implemented in an experimental PPG measurement device, is developed by analyzing a set of PPG data recorded from a group of athletes exercising on a treadmill. An extensive set of tests is carried out during maximal exercise tests on a treadmill to validate the proposed algorithm by comparison with a reference electrocardiography measurement system. The Bland-Altman method is used to compare and evaluate PPG signals. The accuracy of the heartbeat measurement is better than ± 6.5 beats per minute (bpm) ( ≤ 4.2 %) even under maximal exercise conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.