A mandibular implant-retained overdenture is considered a first-choice treatment for edentulism. However, some aspects limit the use of standard implants-for example, the width of edentulous ridges, chronic diseases, fear, or costs. This randomized trial compared mandibular overdentures retained by 2 or 4 mini-implants with standard implants, considering oral health-related quality of life (OHRQoL), patient satisfaction, and complications such as lost implant. In sum, 120 edentulous men and women (mean age, 59.5 ± 8.5 y) randomly received 4 mini-implants, 2 mini-implants, or 2 standard implants. Participants provided data regarding OHRQoL and satisfaction until 12 mo. Clinical parameters, including implant survival rate, were also recorded. Both 2 and 4 mini-implants led to better OHRQoL, compared with 2 standard implants. Treatment with 4 mini-implants was more satisfying than 2 standard implants, with 2 mini-implants presenting intermediate results. Implant survival rate was 89%, 82%, and 99% for 4 mini-implants, 2 mini-implants, or 2 standard implants, respectively. Overdentures retained by 4 or 2 mini-implants can achieve OHRQoL and satisfaction at least comparable with that of 2 standard implants. However, the survival rate of mini implants is not as high as that of standard implants (ClinicalTrials.gov NCT01411683).
Although masticatory function is impaired by the loss of natural teeth and dentures can restore only a fraction of such function, patients can benefit from a simplified protocol for complete denture fabrication to the same extent they would by conventional techniques.
The retention of removable dentures by mini-implants is a relatively recent treatment modality and may lead to minimal post-operative trauma. This study compared post-operative pain and discomfort following the insertion of mini-implants (two or four) or two standard-size implants for the retention of mandibular overdentures. One hundred and twenty edentulous participants (mean age 59.5 ± 8.5 years) were randomly allocated into three groups according to received treatment: (GI) four mini-implants, (GII) two mini-implants or (GIII) two standard implants. Seven days after implant insertion, patients answered questions (100-mm VAS) relating to pain, swelling, and discomfort with chewing, speech and hygiene, considering their experiences during the 1st and 6th day. Groups were compared by two-way anova (α = 0.05). All participants (GI: 38; GII: 42; GIII: 40) were analysed after 7 days. At the 6th day, GI felt significantly higher pain than GII and GIII. GI also reported more difficulty in performing oral hygiene practices than GIII during the 1st day. There was no significant difference between groups for the other questions and periods. No participant suffered unexpected side effects. The use of four mini-implants induces more intense post-operative pain at the 6th day than the insertion of two mini- or conventional fixtures, as well as more difficult oral hygiene on the 1st day. Clinicaltrials.gov, NCT01411683; FAPESP, 2011/00688-7 and 2011/23347-0.
Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones albeit the lesser use of time and resources, without disadvantage for the patient. This study compared a simplified method for complete denture fabrication to a conventional protocol in terms of oral health-related quality of life (OHRQoL), patient satisfaction and denture quality. Forty-two edentulous patients requesting treatment with complete dentures were randomly allocated into two study groups. Group S received dentures fabricated by a simplified method and Group C received conventionally fabricated dentures. Before interventions and after three and 6 months following insertion, OHRQoL and patient satisfaction were analysed by specific instruments. A prosthodontist assessed denture quality 3 months after delivery. Groups presented no difference for OHRQoL, denture quality and general satisfaction. Differences regarding patient satisfaction with some aspects of the dentures were found after 3 months (S > C), but were insignificant at 6 months. It was concluded that the simplified method is able to produce dentures of a quality comparable to those produced by the conventional method, influencing OHRQoL and patient satisfaction similarly.
The use of seven domains for the Oral Health Impact Profile (OHIP)-EDENT was not supported for its Brazilian version, making data interpretation in clinical settings difficult. Thus, the aim of this study was to assess patients' responses for the translated OHIP-EDENT in a group of edentulous subjects and to develop factor scales for application in future studies. Data from 103 conventional and implant-retained complete denture wearers (36 men, mean age of 69.1 +/- 10.3 years) were assessed using the Brazilian version of the OHIP-EDENT. Oral health-related quality of life domains were identified by factor analysis using principal component analysis as the extraction method, followed by varimax rotation. Factor analysis identified four factors that accounted for 63% of the 19 items total variance, named masticatory discomfort and disability (four items), psychological discomfort and disability (five items), social disability (five items) and oral pain and discomfort (five items). Four factors/domains of the Brazilian OHIP-EDENT version represent patient-important aspects of oral health-related quality of life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.