Faulty breathing is an aspect of alteration in the normal fundamental pattern of breathing. The available existence of scales in assessing faulty breathing has not frequently been used. Measurement errors in assessing and quantifying breathing patterns may originate from unclear directions and variation between observers. This study determined the measure reliability of the Total Faulty Breathing Scale (TFBS) for quantifying breathing patterns. Twenty seven participants were recruited comprising healthy and unhealthy subjects. Two examiners assessed their breathing patterns using the TFBS on two different occasions with visual observation and a videogrammetry method. Evaluation of the observational breathing pattern method for intra-rater and inter-rater showed agreement of 96.30% and a kappa score of greater than 0.78, which indicated substantial agreements. The videogrammetry method showed a percent agreement of (100%) with a kappa score of (1.00). This study indicates that the TFBS is a considerably reliable tool for evaluating breathing patterns with both visual observation and a videogrammetry method.
Background and Aims: The evaluation of breathing function is crucial in the clinical examination of the respiratory system. The Total Faulty Breathing Scale (TFBS) could be used in clinical settings to quantify the measurement of breathing dysfunction.Reliability data for the TFBS are available for males, but there is a requirement to determine reliability for females and to develop reference values. The aim of this study, therefore, was to determine the reliability in females and to establish the preliminary reference values for the TFBS.Methods: Twenty-three healthy female participants for reliability and 44 (7 male and 37 female) participants for preliminary reference values participated in this cross-sectional study. For both aspects of the study, participants were instructed to breathe at their own pace with no specific instruction. Then each participant was observed carrying out normal breathing for a period of 10 breaths and deep breathing for a period of 10 breaths while being assessed with the TFBS.Results: Intrarater and interrater reliability of the TFBS showed a kappa value of 0.769 and 0.751, respectively, indicating substantial agreement for female participants. The preliminary reference categories for TFBS were reported to be normal for 20 (45.5%) participants and mild faulty breathing for the remaining 24 (54.4%) participants.
Conclusions:The findings of this study suggested that TFBS was reliable to measure breathing function among female participants, and the reference categories may be helpful in the identification of normal and faulty breathing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.