Purpose: To determine incidence, demographics, management, and outcomes of topical steroid-induced ocular hypertension after penetrating keratoplasty (PKP) and to establish effects on intraocular pressure (IOP) and graft rejection when alternate corticosteroids are used. Methods: A single-center, retrospective review of 568 consecutive PKPs performed between 1997 and 2010 was conducted. Data were collected on demographics, best-corrected visual acuity, surgical indications, lens status, IOP, postoperative management, and incidence of rejection. Results: Eighty eyes (14.1%) of 74 patients were included. The most common indication was keratoconus (28.8%). Twenty-seven eyes (33.8%) were phakic, 46 (57.4%) had a posterior chamber intraocular lens, and 7 (8.8%) had an anterior chamber intraocular lens. Mean postoperative IOP increase was only significant in the anterior chamber intraocular lens group (18.7 mm Hg, SD 10.4; P = 0.02). The average time for developing hypertension was 9.8 months (SD 14.8) postoperatively, with an average IOP increase of 13.3 mm Hg (SD 5.9). Prednisolone acetate 1% was switched to rimexolone 1% in 64 eyes (80%) and to fluorometholone 0.1% in 16 eyes (20%), which alone achieved IOP normalization in 26 eyes (32.5%) (P < 0.01). Fifty-four eyes (67.5%) required additional antiglaucoma medication. An average IOP reduction of 12.3 mm Hg (SD 6.9) was achieved at an average of 2.3 months (SD 5.2) after the switch. Seventeen eyes (21%) developed glaucoma and 13 eyes (16.3%) developed graft rejection after switching formulations, with no statistically significant differences between rimexolone and fluorometholone (P > 0.05). Conclusions: The use of alternate topical corticosteroids may be considered in cases of steroid-induced ocular hypertension after PKP because they offer good antiinflammatory prophylaxis with reduced hypertensive response.
Introduction Endothelial cell density (ECD) changes long after penetrating keratoplasty (PKP) of organ-cultured corneas have been little studied. We aim to calculate the point when ECD decline stabilises following PKP with organ culture stored corneas. Methods This is an observational study of first-ever PKPs and first-ever re-grafts, performed over 17 years under a single surgeon. ECDs were acquired at 3 and 6 months, 1 year post-graft and annually thereafter by specular microscopy. Time-dependent ECD data was fitted to a log-biexponential model. Results We studied 465 first-ever grafts and 128 re-grafts. Mean recipient age was 59 years (range 0–96 years; SD 22). Median follow-up was 5.7 (range 0.2–17.1) years. Probability of ED at 5 years in first grafts and re-grafts was 4.4% (2.6–7.1%) and 14.8% (8.3–23.2%). In first grafts, ECD loss reached 0.6% per annum at 7.9 (6.2–9.6) years post-operatively. The half-lives of ECD loss during the immediate post-operative period for first grafts, re-grafts, dystrophies, ectasias, and previous ocular surgery are 20.1 (14.9–30.9), 12.8 (6.9–79.4), 19.5 (13.1–37.7), 26.2 (16.2–68), and 11.6 (6.7–41.3) months, respectively. The half-life during this rapid phase of ECD loss has an inverse correlation with graft survival at 10 years ( r = − 0.89, p = 0.02). Conclusions Rate of endothelial decompensation is higher in first grafts than re-grafts. ECD decline stabilises 7.9 years post-operatively in first grafts but then becomes lower than the physiological loss expected. Further work is needed to verify whether organ-cultured grafts reach physiological levels of ECD loss faster than hypothermically stored grafts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.