Background This study examined whether ultra-low-dose chest computed tomography (ULD-CT) could improve detection of acute chest conditions. Purpose To determine (i) whether diagnostic accuracy of ULD-CT is superior to supine chest X-ray (sCXR) for acute chest conditions and (ii) the feasibility of ULD-CT in an emergency department. Material and Methods From 1 February to 31 July 2019, 91 non-traumatic patients from the Emergency Department were prospectively enrolled in the study if they received an sCXR. An ULD-CT and a non-contrast chest CT (NCCT) scan were then performed. Three radiologists assessed the sCXR and ULD-CT examinations for cardiogenic pulmonary edema, pneumonia, pneumothorax, and pleural effusion. Resources and effort were compared for sCXR and ULD-CT to evaluate feasibility. Diagnostic accuracy was calculated for sCXR and ULD-CT using NCCT as the reference standard. Results The mean effective dose of ULD-CT was 0.05±0.01 mSv. For pleural effusion and cardiogenic pulmonary edema, no difference in diagnostic accuracy between ULD-CT and sCXR was observed. For pneumonia and pneumothorax, sensitivities were 100% (95% confidence interval [CI] 69–100) and 50% (95% CI 7–93) for ULD-CT and 60% (95% CI 26–88) and 0% (95% CI 0–0) for sCXR, respectively. Median examination time was 10 min for ULD-CT vs. 5 min for sCXR ( P<0.001). For ULD-CT 1–2 more staff members were needed compared to sCXR ( P<0.001). ULD-CT was rated more challenging to perform than sCXR ( P<0.001). Conclusion ULD-CT seems equal or better in detecting acute chest conditions compared to sCXR. However, ULD-CT examinations demand more effort and resources.
Ultra-low dose computed tomography (ULD-CT) assessed by non-radiologists in a medical Emergency Department (ED) has not been examined in previous studies. To (i) investigate intragroup agreement among attending physicians caring for ED patients (i.e., radiologists, senior- and junior clinicians) and medical students for the detection of acute lung conditions on ULD-CT and supine chest X-ray (sCXR), and (ii) evaluate the accuracy of interpretation compared to the reference standard. In this prospective study, non-traumatic patients presenting to the ED, who received an sCXR were included. Between February and July 2019, 91 patients who underwent 93 consecutive examinations were enrolled. Subsequently, a ULD-CT and non-contrast CT were performed. The ULD-CT and sCXR were assessed by 3 radiologists, 3 senior clinicians, 3 junior clinicians, and 3 medical students for pneumonia, pneumothorax, pleural effusion, and pulmonary edema. The non-contrast CT, assessed by a chest radiologist, was used as the reference standard. The results of the assessments were compared within each group (intragroup agreement) and with the reference standard (accuracy) using kappa statistics. Accuracy and intragroup agreement improved for pneumothorax on ULD-CT compared with the sCXR for all groups. Accuracy and intragroup agreement improved for pneumonia on ULD-CT when assessed by radiologists and for pleural effusion when assessed by medical students. In patients with acute lung conditions ULD-CT offers improvement in the detection of pneumonia by radiologists and the detection of pneumothorax by radiologists as well as non-radiologists compared to sCXR. Therefore, ULD-CT may be considered as an alternative first-line imaging modality to sCXR for non-traumatic patients who present to EDs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.