Purpose This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials. Materials and Methods Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed. Results The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45–0.72), sensitivity (0.6–0.67), and specificity (0.23–0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68–0.77, 0.67–083, and 0.53–087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups ( P >0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use ( P <0.05). Conclusion The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.
Resumo: Relatos atuais de vários estudos demonstram que gestantes portadoras de endometriose possuem um risco mais elevado de complicações obstétricas. Vale lembrar que devido a grande maioria das pacientes portadoras de endometriose ser inférteis, é relevante considerarmos que boa parcela dessas gestações seja por reprodução assistida (RA). O nosso estudo através de buscas de artigos no PUBMED, visa revisar a literatura existente e atualizada sobre esse assunto. Os resultados demonstraram na sua grande maioria, que existe um risco mais elevado de realização de cesarianas, hemorragias pré-parto, nascimentos pré-termo e raramente perfuração espontânea de intestino e hemorragia espontânea na gestante. Palavras-chave: endometriose, gestação, risco.
Objectives : The aim of this study was to compare the accuracy of vertical root fracture (VRF) detection using three tomography devices and two software systems in teeth with different endodontic fillings. Methods : The sample consisted of 45 premolars divided into 3 groups: No filling (NF, n=15); Gutta percha (GP, n=15) and Metallic Post (MP, n=15). Cone-beam computed tomography (CBCT) images were acquired in Kodak 9000 3D, Orthopantomography 300 (OP300) and PreXion 3D devices, before and after induced root fractures. Two oral radiologists analyzed all images using InVivoDental and e-Vol DX software systems. The analysis was repeated after 15 days in 30% of the sample. Data analysis compared receiver operating characteristic (ROC) curves, as well the areas under the ROC curves. Accuracy, sensitivity, specificity, positive and negative predictive value were calculated according to each tomographic device and software. Intra- and interexaminer reliability were tested using the Kappa coefficient. Results: The highest accuracy was seen in the image set from the PreXion 3D, using InVivo (0.96) or e-Vol DX (0.92) in image analysis. The OP300 device presented a similar performance of the PreXion 3D in teeth with different endodontic fillings. When using e-Vol DX, the accuracy of Kodak 9000 3D improved from 0.62 to 0.74. Conclusions: The PreXion 3D device is the most accurate when detecting VRF, with a performance similar to the OP300 in endodontic filled teeth. Kodak 9000 3D is indicated for teeth without fillings, with better accuracy using e-Vol DX software.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.