Objectives
The aim of the study was to compare the performance of narrow diameter implants in patients with uncontrolled diabetes mellitus type 2 (T2DM) and normo-glycemic individuals during the first 12 months after implant loading.
Material and methods
In 16 T2DM patients with HbA1C > 6.5% (test group) and 16 normo-glycemic patients (HbA1C < 6.0%; control group), one to two narrow diameter tissue level implants were placed in the posterior maxilla or mandible. After 3-month lasting integration period, implants were loaded by fixed dentures. The clinical parameters probing depth (PD), bleeding on probing (BOP), attachment loss (CAL), recession and papilla bleeding index (PBI) were assessed manually at loading and after 12 months of function. The paired digital periapical radiographs were analyzed with regard to the change in marginal bone level (MBL) from baseline to 12 months’ control. The mean values calculated for both patient groups were statistically analyzed. The technical complications were recorded.
Results
The T2DM group accounted 13 patients due to 3 dropouts. The overall implant survival rate after 12 months was 100%. The differences in means for the clinical parameters and the MBL were statistically non-significant between the T2DM and normo-glycemic patients for the short period of loaded function reported here. No technical complications were recorded.
Conclusions
The study demonstrated an encouraging clinical outcome with narrow diameter implants in patients with uncontrolled T2DM compared to non-diabetics after 12 months post loading. For the short observation period, no biological and technical complications were reported regardless the glycemic status.
Clinical relevance
Patients with HbA1C > 6.5% may benefit from the treatment with narrow diameter implants by avoiding complex surgical interventions with augmentation procedures.
Trial registration
Clinicaltrials.gov: NCT04630691
Objectives: The aim of this prospective case-control study was to compare the development of implant stability quotients of narrow diameter implants in patients with type 2 diabetes mellitus (T2DM) and healthy individuals within the first 3 months after implant insertion.Methods: Sixteen patients with T2DM (HbA1C > 6.5%) as test group and 16 nondiabetic patients (HbA1C < 5.9%) as the control group were evaluated. All patients received narrow-diameter tissue level implants in an edentulous area posterior to the canine. The implant stability was measured by means of resonance frequency analysis after 3 days, 7 days, 4 weeks, and 3 months postplacement.Statistical analysis of intergroup differences and correlation to HbA1c values and treated jaw was performed in PRISM 8.
Results:The means for implant stability quotients showed a significant increase between Day 3 and 3-month assessment in both groups. No significant differences between study groups and no correlation of implant stability to HbA1c were found.
Conclusion:The present study shows encouraging clinical outcomes for narrowdiameter implants inserted in the posterior zone in patients with uncontrolled T2DM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.