Recent guidelines recommend oxygen saturation (SpO2) levels of 90%-95% for preterm neonates on supplemental oxygen but it is difficult to discern such levels with current pulse oximetry sonifications. We tested (1) whether adding levels of tremolo to a conventional log-linear pulse oximetry sonification would improve identification of SpO2 ranges, and (2) whether adding a beacon reference tone to conventional pulse oximetry confuses listeners about the direction of change. Participants using the Tremolo (94%) or Beacon (81%) sonifications identified SpO2 range significantly more accurately than participants using the LogLinear sonification (52%). The Beacon sonification did not confuse participants about direction of change. The Tremolo sonification may have advantages over the Beacon sonification for monitoring SpO2 of preterm neonates, but both must be further tested with clinicians in clinically representative scenarios, and with different levels of ambient noise and distractions.
Objective A study of auditory displays for simulated patient monitoring compared the effectiveness of two sound categories (alarm sounds indicating general risk categories from international alarm standard IEC 60601-1-8 versus event-specific sounds according to the type of nursing unit) and two configurations (single-patient alarms versus multi-patient sequences). Background Fieldwork in speciality-focused high dependency units (HDU) indicated that auditory alarms are ambiguous and do not identify which patient has a problem. We tested whether participants perform better using auditory displays that identify the relevant patient and problem. Method During simulated patient monitoring of four patients in a respiratory HDU, 60 non-clinicians heard either (a) IEC risk categories as single-patient alarm sounds, (b) event-specific categories as single-patient alarm sounds, (c) IEC risk categories in multi-patient spearcon sequences or (d) event-specific categories in multi-patient spearcon sequences. Participants performed a perceptual-motor task while monitoring patients; after detecting abnormal events, they identified the patient and the event. Results Participants hearing multi-patient sequences made fewer wrong patient identifications than participants hearing single-patient alarms. Advantages of event-specific categories emerged when IEC risk category sounds indicated more than one potential event. Even when IEC and event-specific sounds indicated the same unique event, spearcons supported better event identification than did auditory icon sounds. Conclusion Auditory displays that unambiguously convey which patient is having what problem dramatically improve monitoring performance in a preclinical HDU simulation. Application Time-compressed speech assists development of detailed risk categories needed in specific HDU contexts, and multi-patient sound sequences allow multiple patient wellbeing to be monitored.
Much of the focus related to alarm fatigue has been directed towards reducing the number of alarms associated with vital sign monitoring. However, recent fieldwork conducted in four high dependency and critical care units of an Australian hospital suggests that the most problematic alarms were often unassociated with vital signs, such as IV pumps and mattress alarms. Many nurses indicated that they like alarms, even when false, because they support awareness of their patients’ well-being. Results of the fieldwork are guiding the design of a simulation study investigating clinical monitoring displays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.