Comprehensive gas chromatography (GC) has emerged in recent years as the technique of choice for the analysis of volatile and semivolatile compounds in complex matrices. Coupling it with high‐resolution mass spectrometry (MS) makes a powerful tool for identification and quantification of organic compounds. The results obtained in this study showed a significant improvement by using GC×GC‐EI‐MS in comparison with GC‐EI‐MS; the separation of chromatogram peaks was highly improved, which facilitated detection and identification. However, the limitation of Orbitrap mass analyzer compared with time‐of‐flight analyzer is the data acquisition rate; the frequency average was about 25 Hz at a mass resolving power of 15.000, which is barely sufficient for the proper reconstruction of the narrowest chromatographic peaks. On the other hand, the different spectra obtained in this study showed an average mass accuracy of about 1 ppm. Within this average mass accuracy, some reasonable elemental compositions can be proposed and combined with characteristic fragment ions, and the molecules can be identified with precision. At a mass resolving power of 7.500, the scan rate reaches 43 Hz and the GC×GC‐MS peaks can be represented by more than 10 data points, which should be sufficient for quantification. The GC×GC‐MS was also applied to analyze a cellulose bio‐oil sample. Following this, a highly resolved chromatogram was obtained, allowing EI mass spectra containing molecular and fragment ions of many distinct molecules present in the sample to be identified.
Preferential enrichment (PE) is a crystallization process, starting from either a racemic of slightly enantio-enriched solution (ca. +5%) that results in a high enantiomeric excess in the liquid phase (>+90%ee) and a slight opposite excess in the deposited crystals (−2 to −5%ee). The mechanism(s) of this symmetry-breaking phenomenon is (are) still a matter of debate since it eludes rationalization by phase diagram formalism. In this publication, we thoroughly reinvestigate the PE phenomenon of arginine fumarate by using a new approach: the process is monitored by introducing isotopically labeled arginine enantiomers into the crystallization medium to better understand the mass exchanges during crystallization. These experiments are supported by chiral HPLC-MS/MS. This study permits re-evaluating the criteria that were thought mandatory to perform PE. In particular, we show that PE occurs by a continuous exchange between the solution and the crystals and does not require the occurrence of a solvent-mediated solid–solid phase transition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.